David Babakaiff
Written by David Babakaiff · Co-Founder, VanPlex | 25+ Years BC Construction Last reviewed: October 2026

Dallas | Parking, Setbacks and Height

Dallas Parking, Setbacks, Height and Lot Coverage by District

Dallas cut its parking rules on May 14, 2025. A house now needs one space in the single-family, duplex and townhouse districts and none elsewhere, and any use near a light rail or streetcar station needs none. The size of a building is set by yards, height and lot coverage, which differ by district. This page gives the parking rules from the ordinance, the yard and height figures from the City's district summaries, and the ways to ask for less. The Dallas overview gives the short version.

Dallas parking and yards in six facts

Parking Reform of May 14, 2025

The City's parking amendment page says: "On May 14, 2025, Dallas City Council voted 14-1 to adopt Parking Reform for flexible parking in Dallas." The page adds that "the new parking ratios and regulations will apply to the entire Development Code contained in Chapters 51, 51A, 51P, Article XIII: form-based code, and planned development districts where applicable." Off-street parking means spaces on private land, as opposed to on the street.

The law is Ordinance No. 33112, a 171-page PDF that rewrote the parking line of each use. For homes it reads: single family, one space "per dwelling unit in single family, duplex, townhouse, and RTN districts"; duplex, one space "per dwelling unit in D, TH, and RTN districts. None in other districts"; and handicapped group dwelling unit, "None." RTN is one of the City's form districts.

Use Minimum off-street parking Section
Single family One space per unit in single family, duplex, townhouse and RTN districts; none in other districts 51A-4.209(b)(6)(C)
Duplex One space per unit in D, TH and RTN districts; none in other districts 51A-4.209(b)(2)(C)
Handicapped group dwelling unit None 51A-4.209(b)(3.1)(C)
Multifamily, 20 units or fewer None 51A-4.209(b)(5)(C)
Multifamily, 21 to 199 units One-half space per unit, with 10 or 15 percent marked for guests 51A-4.209(b)(5)(C)
Multifamily, 200 units or more One space per unit, with 15 percent marked for guests 51A-4.209(b)(5)(C)
Any use near rail, downtown or historic None, except in the MD-1 overlay 51A-4.301(a)(2)(B)

Source: Dallas Development Code sections as amended by Ordinance No. 33112, passed May 14, 2025.

The ordinance also prints a summary table, Table 1.0.1, which gives single-family parking as "R, D, and TH districts: 1; Otherwise: None" and duplex parking as "D and TH districts: 1 space per unit." The table leaves out the RTN district that the use rules name. The ordinance settles the conflict itself: "If there is a conflict between the table and a parking requirement in Division 51A-4.200, the parking requirement listed in Division 51A-4.200 controls." So the use rules, with RTN, control.

The staff case report explains the change: before it, "the code requires 1 parking space per dwelling unit for uses in R-7.5(A), R-5(A), and TH(A), and two spaces per dwelling unit for the rest of the single family and duplex zoning districts." Staff had proposed no minimum for houses and duplexes; the Council adopted one space in the single-family, duplex and townhouse districts.

Where No Parking Is Required

Sec. 51A-4.301(a)(2)(B) removes the minimum for every use in three kinds of places: "Except when located within the MD-1 Overlay in existence since May 14, 2025, no parking is required for any use if any portion of the lot or established building site containing the use is: (i) within 2,640 feet of a light rail or streetcar station; (ii) in a central area district; or (iii) located on a property designated as a recorded Texas historic landmark, state antiquities landmark, national historic landmark, national register district, or in a local historic district or landmark."

2,640 feet is half a mile, and the test is met if any part of the lot is inside that distance. The central area districts are the downtown districts; the City page names "CA-1 and CA-2 districts (downtown)." MD-1 is the Modified Delta Overlay, Sec. 51A-4.506, which keeps its own parking tables. For a house or duplex, the historic rule means that a lot in a local historic district needs no space at all. The district's own preservation rules stay in force.

Where Parking May Go

The same ordinance restates the rules on the location of parking in Sec. 51A-4.301(a)(4). In residential districts, "except an MF-3(A) or MF-4(A) district, required off-street parking for residential uses must be located behind a required front building line." A building line is the line a building may not cross, usually the edge of the required front yard. "In an MF-1(A), MF-1(SAH), MF-2(A), or MF-2(SAH) district, no required or excess parking may be placed in the required front yard." In MF-3(A) and MF-4(A), parking "may extend to the front property line."

  • "A parking space must be at least 20 feet from the right-of-way line adjacent to a street if the space is located in an enclosed structure and if the space faces upon or can be entered directly from the street." This rule controls over any building line platted to a lesser setback.
  • "Off-street parking is not permitted in a visibility triangle as defined in Section 51A-4.602," the corner area that section sets.
  • "In single family, duplex, townhouse, and CH districts, off-street parking must be provided at or below ground level," except mechanized parking the code approves separately.
  • Wheel stops at least six inches high are required where parking abuts a sidewalk, landscaping or a neighbor, "Except for single family, handicapped group dwelling unit, and duplex uses."

A parking lot of 50 spaces or more needs at least one walkway from the building entrance to the street, and trees within four feet of a parking space need curbs or stops to protect them. These rules matter for an apartment site, and the director can waive them where a street easement or a utility line makes them impossible.

Yards, Height and Lot Coverage by District

A yard, or setback, is the open strip between a building and a lot line. Lot coverage is the share of the lot that buildings may cover. The figures below are for the main residential building type in each district; each summary sets larger side and rear yards for "other permitted structures."

District Front Side Rear Height Coverage
R-1ac(A), R-1/2ac(A) 40 ft 10 ft 10 ft 36 ft 40%
R-16(A) 35 ft 10 ft 10 ft 30 ft 40%
R-13(A) 30 ft 8 ft 8 ft 30 ft 45%
R-10(A) 30 ft 6 ft 6 ft 30 ft 45%
R-7.5(A) 25 ft 5 ft 5 ft 30 ft 45%
R-5(A) 20 ft 5 ft 5 ft 30 ft 45%
D (duplex structure) 25 ft 5 ft 10 ft 36 ft 60%
TH-1(A) to TH-3(A) (house) None None None 36 ft 60%
CH 15 ft on an expressway or thoroughfare, else none 10 ft next to most other districts, else none Same as side 36 ft 60%
MF-1(A), MF-2(A) (apartments) 15 ft 10 ft 15 ft 36 ft 60%
MF-3(A) 15 ft, plus 20 ft above 45 ft of height 20 ft next to listed residential districts, else 10 ft Same as side 90 ft 60%
MF-4(A) 15 ft, plus 20 ft above 45 ft of height 20 ft next to listed residential districts, else 10 ft Same as side 240 ft 80%

Source: City of Dallas Current Planning district summaries (for example R-7.5(A), R-5(A), D, CH, MF-3(A)), read October 9, 2026. Coverage is for residential structures.

Every summary carries the same warning: "Setbacks may be greater or lesser due to exceptions in the Dallas Development Code, exceptions include, but not limited to, platted building lines and more restrictive zoning district setbacks in the same block." A platted building line is a line drawn on the recorded plat, and it can require a deeper front yard than the district does. The City Plan Commission agendas for 2026 list 12 replats that ask to remove, reduce or extend a platted building line, such as a 30-foot line on Caruth Boulevard and a 65-foot line on Park Lane.

Coverage and stories. Coverage is 40 percent in R-16(A) and the half-acre and one-acre districts, 45 percent in R-13(A) to R-5(A), and 60 percent in the duplex, townhouse and CH districts. The summaries say "Above ground parking structures are included in lot coverage calculations" and "Surface parking lots and underground parking structures are not." Each lists "No maximum number of stories," so height in feet is the limit.

Tall buildings. In MF-3(A) and MF-4(A), "An additional 20 foot front yard setback is required for that portion of a structure over 45 feet in height," and "An additional side and rear yard setback of one foot for each two feet in height above 45 feet is required," up to a total of 30 feet. The side and rear yard is 20 feet where the lot is next to or across an alley from the R, D, TH, CH, MF-1 or MF-2 districts.

Accessory buildings. Ordinance No. 30930 limits a garage, shed or other accessory structure on a house lot: "The height of an accessory structure may not exceed the height of the main building," and its floor area may not exceed 25 percent of the main building's. Neighborhood stabilization overlays can add a height plane on top of the district height; the overlay page explains it.

Asking for Less: Variances and Reductions

The Board of Adjustment can grant a variance, a permission to depart from a rule on one lot. The 2026 Meadow Street report quotes Sec. 51A-3.102(d)(10): the Board "has the power to grant variances from the front-yard, side-yard, rear-yard, lot-width, lot-depth, lot-coverage, floor area for structures accessory to single-family uses, height, minimum sidewalks, off-street parking or off-street loading, or landscape regulations." The lot must differ from others by being "of such a restrictive area, shape, or slope" that it cannot be developed like other lots in the district, and the variance may not be "granted to relieve a self-created or personal hardship, nor for financial reasons only."

The Permit Fee Schedule effective July 1, 2025 lists a single-family variance at $600, a multifamily or nonresidential variance at $900 plus $25 per acre, and a variance or special exception to off-street parking at $900 plus $100 for each parking space variance or special exception requested. An administrative parking reduction, which staff decide, is "$375 and $25 per additional space over 10."

SB 15 small lots. On a lot of 4,000 square feet or less platted under SB 15, state law sets the upper limits, whatever the district says: a city may not require a setback greater than 15 feet in front, 10 feet in back or five feet on the side, more than one parking space per unit, covered parking, or a height limit below three full stories. Dallas Ordinance No. 33192 lets the building official permit a structure there that meets Section 211.055. The lot size page covers those plats.

Best For

  • ✓ A lot within half a mile of a DART light rail or streetcar station, where no parking minimum applies.
  • ✓ A townhouse or MF-1(A) to MF-2(A) site, where small yards and 60 percent coverage leave room for several homes.
  • ✓ A house in a local historic district, which needs no parking space.

Usually Fails When

  • ✕ The design counts on the district front yard and the recorded plat shows a deeper building line.
  • ✕ A garage faces the street less than 20 feet from the right-of-way line.
  • ✕ The lot is inside the MD-1 overlay and the plan assumes the rail station exemption.

What To Verify Before Spending Money

  • → The building lines on your recorded plat and any stricter setbacks on the same block.
  • → The distance from the lot to the nearest light rail or streetcar station, measured to any part of the lot.
  • → Any overlay, conservation district or PD rule that changes the yards or height.

Where to Go Next

Related on VanPlex: the Dallas overview and the SB 15 small lots page.

Frequently Asked Questions

How many parking spaces does a new house need in Dallas? +
A new Dallas house needs one off-street parking space in single family, duplex, townhouse and RTN districts, and none in other districts, under Sec. 51A-4.209(b)(6)(C) as amended by Ordinance No. 33112 on May 14, 2025. The staff report says the code had required two spaces outside R-7.5(A), R-5(A) and TH(A). No space is needed within 2,640 feet of a light rail or streetcar station.
Can I park in my front yard in Dallas? +
Required parking for a Dallas home must sit behind the required front building line in residential districts other than MF-3(A) and MF-4(A), under Sec. 51A-4.301(a)(4)(F) as restated by Ordinance No. 33112. In MF-1(A) and MF-2(A) no required or excess parking may go in the required front yard. A garage space that opens onto the street must be at least 20 feet from the right-of-way line.
What is the front setback for a house in Dallas? +
The Dallas front yard for a house depends on the district. The City summaries set 20 feet in R-5(A), 25 feet in R-7.5(A), 30 feet in R-10(A) and R-13(A), 35 feet in R-16(A) and 40 feet in the half-acre and one-acre districts. Townhouse districts have no minimum front yard. Platted building lines and stricter setbacks on the same block can change the figure.
How tall can a house be in Dallas? +
A Dallas house can be 30 feet tall in the R-16(A), R-13(A), R-10(A), R-7.5(A) and R-5(A) districts and 36 feet in R-1ac(A), R-1/2ac(A), D and the townhouse districts, by the City district summaries, which list no maximum number of stories. A neighborhood stabilization overlay can add a height plane that starts six feet above the center of the street.
How much of a Dallas lot can a house cover? +
A Dallas house may cover 45 percent of the lot in R-5(A), R-7.5(A), R-10(A) and R-13(A), and 40 percent in R-16(A) and the half-acre and one-acre districts, by the City district summaries. Duplex, townhouse and CH districts allow 60 percent. Aboveground parking structures count toward lot coverage; surface parking lots and underground garages do not.
Are Dallas setbacks always the numbers in the district summary? +
No. Each Dallas district summary warns that "Setbacks may be greater or lesser due to exceptions in the Dallas Development Code," naming platted building lines and stricter zoning district setbacks on the same block. A building line printed on your recorded plat can require a deeper front yard than R-5(A) or R-7.5(A) does, and a replat is the way to remove one.
Can the Dallas Board of Adjustment reduce a setback? +
Yes. Sec. 51A-3.102(d)(10), quoted in 2026 Dallas Board of Adjustment case reports, lets the Board grant variances from front, side and rear yard, lot width, lot depth, lot coverage, height and off-street parking rules. The lot must differ from others by being restrictive in "area, shape, or slope," and the hardship may not be self-created or only financial. The single-family variance fee is $600.
Does parking reform apply to planned development districts in Dallas? +
Yes, where applicable. The City parking amendment page says that with the May 14, 2025 adoption, "the new parking ratios and regulations will apply to the entire Development Code contained in Chapters 51, 51A, 51P, Article XIII: form-based code, and planned development districts where applicable." Ask Planning and Development staff how it applies to the planned development district on your lot.
What is the MD-1 overlay in the Dallas parking rules? +
MD-1 is the Modified Delta Overlay district, Sec. 51A-4.506 of the Dallas Development Code. Ordinance No. 33112 keeps separate parking tables for some uses there and leaves out of the no-minimum rule any use "within the MD-1 Overlay in existence since May 14, 2025," so the rail station, downtown and historic exemptions do not reach those lots. Check the MD-1 tables if your lot is inside it.
How much does a Dallas parking variance or reduction cost? +
The Dallas Permit Fee Schedule effective July 1, 2025 lists a Board of Adjustment variance or special exception to off-street parking at $900 plus $100 for each parking space requested. An administrative parking reduction, decided by staff, is $375 plus $25 for each space over 10. Since May 2025 many homes need no parking at all, so check the new minimum before you apply.

Official sources (checked October 2026)

City of Dallas, parking code amendment page
https://dallascityhall.com/departments/pnv/Pages/parking-code-amendment.aspx
City of Dallas, Ordinance No. 33112 (parking and loading, May 14, 2025, PDF)
https://citysecretary2.dallascityhall.com/resolutions/2025/05-14-25/25-0763.pdf
City of Dallas, parking amendment staff case report, DCA190-002 (PDF)
https://cityofdallas.legistar1.com/cityofdallas/attachments/477cb2c5-5bb0-474b-a67f-78087cb69510.pdf
City of Dallas Current Planning, R-7.5(A) district summary
https://dallascityhall.com/departments/sustainabledevelopment/planning/Pages/R75A.aspx
City of Dallas Current Planning, R-5(A) district summary
https://dallascityhall.com/departments/sustainabledevelopment/planning/Pages/R5A.aspx
City of Dallas Current Planning, R-16(A) district summary
https://dallascityhall.com/departments/sustainabledevelopment/planning/Pages/R16A.aspx
City of Dallas Current Planning, D duplex district summary
https://dallascityhall.com/departments/sustainabledevelopment/planning/Pages/Duplex.aspx
City of Dallas Current Planning, TH-1(A) district summary
https://dallascityhall.com/departments/sustainabledevelopment/planning/Pages/TH1.aspx
City of Dallas Current Planning, MF-3(A) district summary
https://dallascityhall.com/departments/sustainabledevelopment/planning/Pages/MF3A.aspx
City of Dallas, Ordinance No. 30930 (accessory structures, June 27, 2018, PDF)
https://dallascityhall.com/departments/sustainabledevelopment/planning/DCH%20Documents/code%20amendments/ADUs/30930_BDA_ADU_Ord.PDF
Board of Adjustment case report, 3520 Meadow Street, March 2026 (PDF)
https://cityofdallas.legistar1.com/cityofdallas/attachments/9a1ae8a5-17ab-4c9a-b678-643036ecf401.pdf
City of Dallas, Permit Fee Schedule effective July 1, 2025 (PDF)
https://dallascityhall.com/departments/sustainabledevelopment/buildinginspection/DCH%20documents/DSDFees%20%281%29.pdf
Local Government Code 211.055 (small lots, SB 15)
https://statutes.capitol.texas.gov/Docs/LG/htm/LG.211.htm#211.052
VanPlex newsletter

Get new guides by email

New VanPlex guides and articles on multiplex rules, building costs and permits, sent to your inbox.

General information, not legal advice. Texas has no statewide zoning code. Each city writes its own rules, and deed restrictions recorded on a lot can forbid what the city allows. Confirm current requirements with the city planning department, read the deed restrictions for your lot, and talk to a Texas-licensed attorney or architect before you buy land or file plans.

Planning a multiplex in Dallas?

VanPlex builds multiplexes in British Columbia, Canada. For a lot in Dallas, our team makes a custom proforma by hand and emails it to you in 24 to 48 hours.