Bill 44 Active — Updated March 2026
Port Coquitlam SSMUH Multiplex & Gentle Density Guide
Port Coquitlam's RS-zoned properties now allow 3 to 6 dwelling units depending on lot size and transit proximity. Following initial SSMUH amendments in June 2024, Council adopted further bylaw amendments on June 23, 2025 to support implementation. New duplexes, triplexes, and ADUs require an SSMUH Development Permit before a building permit can be issued. With three Transit Oriented Areas and a housing target of 2,279 net new units by 2029, PoCo is one of the Tri-Cities' strongest markets for missing middle development.
Source: City of Port Coquitlam, SSMUH program page and Zoning Bylaw No. 3630 (2008), as amended.
Port Coquitlam's SSMUH Framework
Port Coquitlam's SSMUH regulations operate under the city's Zoning Bylaw No. 3630 (2008), as amended to comply with BC's Bill 44 Small-Scale Multi-Unit Housing legislation. The initial SSMUH amendments were adopted in June 2024, with parking regulation changes under Bylaw No. 4375 following concurrently.
On June 23, 2025, Council adopted further bylaw amendments to the Zoning Bylaw and Subdivision Servicing Bylaw No. 2241 to support SSMUH implementation. The RS1, RS2, RS3, and RS4 zones now permit small-scale multi-unit housing on eligible lots under 4,050 m2. Port Coquitlam's housing target under the provincial framework is 2,279 net new units by July 31, 2029.
Important: SSMUH units are prohibited on RS-zoned properties that fall within designated Transit Oriented Areas. Those properties follow separate, typically higher-density zoning rules. Additionally, new duplexes, developments with 3 or more dwellings, or ADUs require an SSMUH Development Permit before a building permit can be issued.
Key regulatory changes
- Initial SSMUH amendments adopted June 2024 to Zoning Bylaw No. 3630 (2008).
- June 23, 2025: Council adopted further bylaw amendments to Zoning Bylaw No. 3630 and Subdivision Servicing Bylaw No. 2241 to support SSMUH implementation.
- RS1, RS2, RS3, and RS4 zones updated to permit small-scale multi-unit housing.
- Up to 6 units permitted on lots over 280 m2 within 400 m of frequent bus service (typically along Lougheed Highway).
- SSMUH Development Permit required for new duplexes, 3+ dwelling developments, or ADUs before building permit issuance.
- SSMUH units prohibited on RS-zoned properties within designated Transit Oriented Areas (separate rules apply).
- Building height increased from 7.5 m to 11.0 m (3 storeys) for SSMUH developments.
- Parking minimums eliminated in Transit Oriented Areas and within 400 m of frequent transit.
- Lots over 4,050 m2 excluded from SSMUH eligibility.
- 2026 outlook: City staff reviewing policies for townhouses, rowhouses, and intensive small-scale residential development.
Unit Allowances by Lot Size & Transit
| Lot Size | Location | Max Units |
|---|---|---|
| ≤ 280 m2 | Any eligible RS-zoned lot | 3 units |
| > 280 m2 | Outside 400 m of frequent bus stop | 4 units |
| > 280 m2 | Within 400 m of frequent bus stop | 6 units |
| > 4,050 m2 | Any location | Excluded |
6-unit developments consist of a triplex plus secondary suites. SSMUH is prohibited on RS-zoned lots within designated Transit Oriented Areas. Source: City of Port Coquitlam SSMUH Page
Lots up to 280 m2 (3,014 sq ft)
Up to 3 units
Applies to all eligible RS1-RS4 zoned lots under this size threshold.
Lots over 280 m2 — outside transit
Up to 4 units
Standard allowance for larger lots not within 400 m of a frequent bus stop.
Lots over 280 m2 — within 400 m of frequent transit
Up to 6 units
Triplex plus secondary suites. Lot must be within 400 m of frequent bus service, typically along Lougheed Highway.
Port Coquitlam RS Zone Subdivision Standards
SSMUH applies across four RS zones in Port Coquitlam, each with distinct minimum lot sizes and frontage requirements. Understanding your zone determines subdivision potential and unit configurations.
| Zone | Min Lot Area | Min Width | Description |
|---|---|---|---|
| RS1 | 500 m2 | 15 m | Standard single-family residential |
| RS2 | 375 m2 | 12 m | Compact single-family residential |
| RS3 | 4,000 m2 | 30 m | Large-lot residential |
| RS4 | 300 m2 | 9.5 m | Small-lot residential |
Exclusions & Special Considerations
- SSMUH units are prohibited on RS-zoned properties within designated Transit Oriented Areas (separate density rules apply)
- Lots greater than 4,050 m2 are excluded from SSMUH eligibility
- RS3 zone (4,000 m2 minimum, 30 m width) — large-lot properties with distinct development potential
- Hazard lands, heritage properties, and sites without municipal water/sewer may be subject to additional restrictions
Transit Oriented Areas (TOAs) in Port Coquitlam
Three Transit Oriented Areas influence development in Port Coquitlam. Within TOAs, parking minimums are eliminated and separate density rules apply that are typically more permissive than SSMUH.
Key distinction: SSMUH units are prohibited on RS-zoned properties within designated Transit Oriented Areas. If your lot falls within a TOA, it follows the TOA's own zoning and density framework rather than the SSMUH rules described on this page. Confirm your lot's status with Port Coquitlam Planning.
Category 1 TOA
Coquitlam Central Station
SkyTrain station with frequent transit connections. Highest density allowances.
Category 1 TOA
Lincoln Station
SkyTrain station. Category 1 designation enables maximum unit counts and eliminated parking.
Category 2 TOA
Port Coquitlam WCE Station
West Coast Express commuter rail station. Category 2 designation with transit-oriented density bonuses.
SSMUH Development Permit Requirement
All new duplexes, developments with 3 or more dwellings, and accessory dwelling units require an SSMUH Development Permit before a building permit can be issued. This applies to projects on RS-zoned lots outside of designated Transit Oriented Areas.
Housing forms you can build
Port Coquitlam's SSMUH framework supports multiple gentle density housing types across RS zones. Combine configurations to maximize unit count and development potential based on your lot size and transit proximity.
Duplexes with secondary suites
Two principal units with the ability to add secondary suites. FSR of approximately 0.75 for duplex configurations.
Triplexes (up to 6 units near transit)
Three principal units plus secondary suites on lots within 400 m of frequent transit, reaching up to 6 dwelling units total with 1.00 FSR.
Fourplexes
Four units on lots over 280 m2 outside transit areas. A balanced approach to gentle density in standard residential neighborhoods.
Accessory dwelling units (ADUs)
Up to 90 m2 (968 sq ft), max 2 storeys, height 7.5-8.5 m depending on roof slope. Requires 1 independently accessible parking space.
Key regulations snapshot
These baseline standards guide envelope design for SSMUH projects in Port Coquitlam. Confirm current limits with the Planning Department before submitting drawings.
Floor Space Ratio (FSR)
Approximately 0.70 FSR for 3-unit developments, 0.75 FSR for duplexes, and up to 1.00 FSR for triplex/6-unit configurations near transit.
Building Height
Pre-SSMUH: 7.5 m (up to 9.0 m with steep roof pitch). Under SSMUH: up to 11.0 m and 3 storeys for multiplex development.
ADU Height & Size
ADU height ranges 7.5-8.5 m depending on roof slope, maximum 2 storeys. Maximum floor area is 90 m2 (968 sq ft).
Maximum Building Depth
18.0 m maximum building depth applies across RS zones to maintain rear yard amenity space.
Setbacks & Coverage
- Front yard
- 4.0-6.0 m (reduced if lane/transit)
- Side yard
- 1.2-1.8 m
- Max building depth
- 18.0 m
- Lot coverage
- 45-50%
Parking Requirements
- Within Transit Oriented Area (TOA): Parking minimums eliminated entirely
- Within 400 m of frequent transit: No minimum parking requirements
- ADU parking: 1 independently accessible parking space per ADU
How VanPlex Supports Port Coquitlam SSMUH Projects
Concept to Permit
We coordinate architects, engineers, and consultants to ensure your Port Coquitlam SSMUH project aligns with Zoning Bylaw No. 3630 and your specific RS zone. From navigating the SSMUH Development Permit process to building permit issuance, we handle the regulatory complexity for developments of every scale.
Feasibility Analysis
Comprehensive analysis of your Port Coquitlam lot's SSMUH potential, including RS zone classification, transit proximity, TOA eligibility, unit configurations, and pro forma projections.
Request Your Port Coquitlam SSMUH Feasibility
Share your Port Coquitlam address to receive a tailored analysis including your RS zone, unit allowance, transit proximity, parking requirements, and development pro forma.
Getting Started with Port Coquitlam SSMUH
Before beginning your Port Coquitlam SSMUH project, address these key considerations:
- Confirm your lot's RS zone (RS1, RS2, RS3, or RS4) and applicable subdivision standards.
- Determine proximity to frequent transit stops — lots within 400 m qualify for 6 units and zero parking.
- Check whether your property falls within a designated Transit Oriented Area — SSMUH is prohibited within TOAs (different rules apply).
- Plan for the SSMUH Development Permit process, which must be completed before you can apply for a building permit.
- Review site-specific constraints including easements, environmental considerations, and servicing requirements.
- Confirm ADU requirements: 90 m2 max size, 1 independently accessible parking space.
- Watch for 2026 policy updates — City staff are reviewing rules for townhouses, rowhouses, and intensive small-scale residential development.
Contact Port Coquitlam Planning: For zoning questions, call 604-927-5442 or email planning@portcoquitlam.ca. City Hall: 2580 Shaughnessy Street, Port Coquitlam, BC V3C 2A8.
Official Port Coquitlam SSMUH Resources
Provincial Housing Legislation
Official overview of Bill 44 implementation in Port Coquitlam
SSMUH Development Page
Small-scale multi-unit housing development information and guidelines
SSMUH Development Permits
Development permit requirements for duplexes, 3+ unit developments, and ADUs
Bylaw No. 4374 (PDF)
Initial SSMUH zoning amendment to Bylaw 3630
Property Development & Building
General development information, permits, and building services
Keep exploring
More multiplex support for Port Coquitlam
Dive deeper into British Columbia's gentle density rollout with provincial guidance, statewide policy explainers, and practical tools that keep your Port Coquitlam multiplex project on track.
Design Guidelines Hub
Explore BC's standardized multiplex designs, building code requirements, cost analysis, and permit process -- all in one place.
Browse design guidelines →BC SSMUH Guide
Understand provincial requirements, municipal adoption timelines, and VanPlex's delivery pillars for small-scale multi-unit housing.
Explore the guide →Gentle Density Playbook
Compare multiplex, rowhouse, and cottage court project strategies while you plan your Port Coquitlam build-out.
View the playbook →All City Zoning Maps
Review zoning overlays, transit areas, and servicing considerations across Metro Vancouver, Tri-Cities, and Fraser Valley municipalities.
Browse maps →Multiplex & SSMUH Glossary
Decode Bill 44 terminology -- FSR, stratification, gentle density, and more -- so you can speak the same language as planners and lenders.
Learn the terms →