David Babakaiff
Written by David Babakaiff · Co-Founder, VanPlex | 25+ Years BC Construction Last reviewed: October 2026

Austin | Three or More Homes

Three or More Homes on an Austin Lot: Three-Unit Use, Townhouses, MF Districts and SB 840

Austin's Land Development Code (LDC) permits three homes on one lot in the SF-1, SF-2 and SF-3 districts. A fourth home on that lot is a different use, and the code places it in other districts. This page gives the rules for the three-unit use, then the four routes to more homes: townhouses, condominiums, the multifamily (MF) districts, and the state law SB 840 on office and commercial land. The Austin overview gives the short version.

Three or more homes in Austin in six facts

Five Routes to Three or More Homes

Section 25-2-3 defines three-unit residential use as "the use of a lot for three dwelling units other than a mobile home," and multifamily residential use as the use of a site for four or more dwelling units. A dwelling unit is a home with its own space for living, sleeping, eating and cooking. The use table in Section 25-2-491 then places each use in its districts.

Route Districts Main size rule
Three-unit residential use SF-1, SF-2, SF-3 Lot of 5,750 sq ft; 3 homes at most
Townhouses SF-5, SF-6, MF-1 to MF-6 3,600 sq ft of site for each townhouse; lots 20 feet wide
Condominiums SF-5, SF-6, MF-1 to MF-6 Site of 14,000 sq ft; 3,500 sq ft of site for each home
Multifamily (four or more homes) MF-1 to MF-6 Lot of 8,000 sq ft; 800 to 3,500 sq ft of site for each home
Housing under SB 840 Office and commercial zones the state law covers Density of 54 units per acre, by the City's briefing

Sources: Austin LDC 25-2-491, 25-2-492, 25-2-560 to 25-2-563, 25-2-773, 25-2-775 and 25-2-776, Supplement 174; City of Austin SB 840 briefing of September 24, 2025.

The Three-Unit Use in SF-1, SF-2 and SF-3

The Council created the three-unit use with HOME Phase 1, Ordinance No. 20231207-001, which applies to applications filed on or after February 5, 2024. The City's HOME amendments page describes it: "A three-unit residential use consists of up to three dwelling units on a lot, which may be attached or detached in any combination." Three detached cottages, a duplex with a separate home, and one building of three homes are all the same use.

Section 25-2-773 gives one set of site rules to duplex, two-unit and three-unit uses. The lot must have at least 5,750 square feet. The front yard setback is 15 feet, and the rear setback is the base district figure or 5 feet next to an alley. A setback is the distance a building must keep from a lot line. At least one entrance faces the street. Building coverage, the share of the lot under roofs, may reach 40 percent. Impervious cover, the share under any surface that stops water from soaking into the ground, may reach 45 percent. The duplexes and second units page has the full table.

Those two percentages are the same for two homes and for three. On a 5,750 square foot lot, 40 percent is 2,300 square feet of roof for all three homes together. Height is the base district figure, 35 feet in SF-1, SF-2 and SF-3, so three homes on a minimum lot use more than one floor.

Floor Area for Three Homes

Inside the area drawn in Section 1.2.1 of Subchapter F, the City's residential design rules for its central neighborhoods, Subsection (E) of Section 25-2-773 sets a floor-to-area ratio. That ratio is the floor area of the buildings divided by the area of the lot. For a three-unit use the subsection has three limits:

  • The site. "The maximum floor-to-area ratio for the site is the greater of 0.65 or 4,350 square feet."
  • One home. Except for an existing dwelling unit, a dwelling unit may not exceed the greater of 0.4 or 2,300 square feet.
  • Two homes together. Two dwelling units may not exceed the greater of 0.55 or 3,200 square feet if an existing unit on the site is not preserved. If an existing unit is preserved under Subsection (F), the figure for two units is the greater of 0.65 or 4,350 square feet.
Lot area All three homes Two homes, no unit preserved Largest new home
5,750 sq ft 4,350 sq ft 3,200 sq ft 2,300 sq ft
7,000 sq ft 4,550 sq ft 3,850 sq ft 2,800 sq ft
8,500 sq ft 5,525 sq ft 4,675 sq ft 3,400 sq ft
10,000 sq ft 6,500 sq ft 5,500 sq ft 4,000 sq ft

VanPlex arithmetic from the formulas in Austin LDC 25-2-773(E)(4): the greater of 0.65 times the lot area or 4,350 sq ft, the greater of 0.55 times the lot area or 3,200 sq ft, and the greater of 0.4 times the lot area or 2,300 sq ft.

The two-home limit shapes the design, and the code does not say which two of the three homes it is measured on. Ask the City's residential reviewers how they apply it to your plan. Three equal homes meet it on any reading. On a 5,750 square foot lot with no house kept, three homes of 1,450 square feet come to 4,350 in total and 2,900 for any two. Garages count toward these figures because they are enclosed, by the City's HOME page, and carports and porches are left out.

The preservation bonus of Subsection (F) applies to three-unit projects too. An owner who keeps at least 50 percent of a qualifying older house may leave the preserved floor area out of the calculation. Outside the Subchapter F area the section sets no floor area figure.

Triplex Review and the Site Plan Exemption

The City separates a triplex from other three-unit layouts. Its HOME page says a triplex is "defined as a single building containing three attached units," and that a City policy memo, PM2024-0002, sets the criteria for reviewing one. An applicant for a triplex submits a Request for Modification or Alternate Method of Compliance form with the permit application. The form is not required for three detached homes or for a duplex with a single home. The building codes page explains where the residential building code stops in Texas.

A site plan is the detailed drawing set that development must have approved before a permit, unless the code exempts it. Section 25-5-2 exempts "construction or alteration of four or fewer residential units" when the legal lot will hold four or fewer units in total and the work is outside the 100-year floodplain, or the director finds an insignificant effect on the waterway. A three-unit project therefore files a residential building permit application with no site plan. The exemption reaches four homes, although the SF districts stop at three, so the fourth home is useful only where the zoning allows it.

Two other rules treat three homes like one or two. The compatibility standards, which limit the height of larger buildings near houses, do not apply to a site used for three-unit residential use. And a lot with one to three homes that is zoned SF-5 or more restrictive is a "triggering property": a site zoned MF-4 or less restrictive within 75 feet of it must meet those limits.

Townhouses and Condominiums in SF-5 and SF-6

The use table permits townhouse and condominium uses from SF-5 upward. A townhouse is a home with a common wall with the next one, on its own lot. Section 25-2-775 sets the rules:

  • "Not more than one townhouse is permitted on a townhouse lot."
  • The minimum lot width for a townhouse is 20 feet.
  • "At least 3,600 square feet of site area is required for each townhouse."
  • At least two connected townhouses are required on a townhouse site.
  • A driveway that serves one townhouse and sits in its front yard may not be wider than 50 percent of the lot width.
  • In SF-5, a townhouse group with access to a local residential street may have no more than six townhouses and must be at least 100 feet from other such groups. On another kind of street the figures are ten townhouses and 300 feet.

The site area rule sets the count. Three townhouses need 10,800 square feet of site and four need 14,400. Section 25-2-61 describes SF-6 as the district that is free of the spacing and location rules that apply to these uses in SF-5. When townhouse lots are platted, Section 25-4-231 requires common areas to be shown on the plat, with a legal opinion on who owns and maintains them.

Condominium residential use is the use of a site for attached or detached condominiums, as the Texas Property Code defines them. Section 25-2-776 says: "The minimum site area for a condominium residential use is 14,000 square feet." At least 3,500 square feet of site area is required for each condominium, so a site of the minimum size holds four. In SF-5 a condominium site may include no more than ten units, must be at least 300 feet from other condominium sites in SF-5, and is prohibited on a site with access only to a local residential street. A condominium use with fewer than 10 homes provides private personal open space of at least 5 percent of the gross site area.

Four or More Homes in the MF Districts

Multifamily residential use is permitted in the six MF districts. The minimum lot is 8,000 square feet and 50 feet wide in each. The number of homes comes from a site area for each home, set by district and by bedrooms in Sections 25-2-560 to 25-2-563. An efficiency is a unit of not more than 400 square feet with no separate bedroom.

District Site area for each home (efficiency / one bedroom / two or more) Maximum height Building coverage Impervious cover
MF-1 2,500 / 3,000 / 3,500 sq ft 40 feet 45% 55%
MF-2 1,600 / 2,000 / 2,400 sq ft 40 feet or 3 stories 50% 60%
MF-3 1,200 / 1,500 / 1,800 sq ft 40 feet 55% 65%
MF-4 800 / 1,000 / 1,200 sq ft 60 feet 60% 70%
MF-5 800 / 1,000 / 1,200 sq ft 60 feet 60% 70%
MF-6 No figure in the code 90 feet 70% 80%

Sources: Austin LDC 25-2-560 to 25-2-563 and 25-2-492(D), Supplement 174.

A four-home building on an MF lot keeps the site plan exemption of Section 25-5-2. From five homes up a site plan is needed, and the code has a lighter process for small sites. Section 25-5-3 lists "construction of five to 16 dwelling units on a lot that does not exceed a gross site area of 1.50 acres" as a small project, for which the director may waive submittal items that are not essential. Section 25-1-21 defines a residential infill project as development of a site of no more than 1.00 acre with five to sixteen dwelling units, and under Section 25-5-112, if the standards are met, "the director shall approve a site plan for a residential infill project in 90 days." These rules came from Ordinance No. 20250306-037, and the City's HOME page says applications under it were accepted from June 16, 2025.

Three more rules apply to small apartment buildings. Under Section 25-2-780, a multifamily use with fewer than 10 homes provides private personal open space of at least 5 percent of the gross site area. Section 25-7-67 lets a residential infill project meet modified drainage rules when a drainage plan shows that all stormwater runoff will go to an existing storm drainage system or into the right-of-way. And the compatibility standards apply to a site zoned MF-4 or less restrictive within 75 feet of a triggering property: a structure may not exceed 40 feet within 50 feet of that property, or 60 feet from 50 to 75 feet. A lot in a single-family district needs a rezoning to become MF land, which the zoning districts page explains.

SB 840: Housing on Office and Commercial Land

SB 840 is a 2025 state law that took effect on September 1, 2025. It added Local Government Code chapter 218, which applies to a city of more than 150,000 people in a county of more than 300,000. Under Section 218.101, "a municipality shall allow mixed-use residential use and development or multifamily residential use and development in a zoning classification that allows office, commercial, retail, warehouse, or mixed-use use or development." The city may not require a rezoning or a variance first. In the statute, multifamily residential means three or more dwelling units on a site.

Austin's planning staff presented the law to the Codes and Ordinances Joint Committee on September 24, 2025. The briefing lists the Austin zones where residential is allowed by right: the office zones NO, LO and GO, and the commercial zones CR, LR, GR, L, CBD, DMU, W/LO, CS and CH. It also names AG, and PUD and R&D zoning that allows commercial uses and prohibits heavy industrial uses. The statute excludes a zoning classification that allows heavy industrial use, land within 1,000 feet of an existing heavy industrial use, and land within 3,000 feet of an airport or military base.

The briefing also gives the minimum rights. A city must allow the greater of 36 units per acre or the highest residential density it allows anywhere: "This is 54 units per acre in Austin." It must allow a height of the greater of 45 feet or the height that applies to a non-residential use on the same site. It may require setbacks no larger than the lesser of 25 feet or the commercial setback, and it may not limit the floor-to-area ratio.

Here the published code and state law differ. The use table in Section 25-2-491, as printed in Supplement 174, still marks multifamily residential as not permitted in NO, LO, GO, LR, GR and CS. Section 218.101 opens with the words "Notwithstanding any other law," and the City's own briefing treats housing as allowed in those zones, so the state law controls where it applies. The briefing listed one next step for the code, a base height for the Central Business District, and the table in Section 25-2-492 now shows a maximum height of 350 feet for CBD after Ordinance No. 20251023-063. Ask the City to confirm that a site is covered before you buy it for this purpose. The SB 840 page covers the statute, including its rules for converting office buildings.

Best For

  • ✓ A lot of 5,750 sq ft or more in SF-1, SF-2 or SF-3, where three homes need no rezoning and no site plan.
  • ✓ An SF-6 site of 14,000 sq ft or more, which holds four condominiums or three townhouses.
  • ✓ An MF site of up to 1.00 acre with five to sixteen homes, which the code treats as a residential infill project.

Usually Fails When

  • ✕ The plan needs a fourth home on a lot zoned SF-1, SF-2 or SF-3.
  • ✕ Three homes with garages exceed 4,350 sq ft on a minimum lot inside the Subchapter F area.
  • ✕ A commercial site is within 3,000 feet of an airport or 1,000 feet of a heavy industrial use, where SB 840 does not apply.

What To Verify Before Spending Money

  • → Whether the design is a triplex, which needs the Alternate Method of Compliance form.
  • → The site area for each home in the MF district, by number of bedrooms.
  • → With the City, whether a commercial site is one that SB 840 covers.

Where to Go Next

Related on VanPlex: the Austin overview, SB 840 on housing in commercial zones, and building codes from duplex to fourplex.

Frequently Asked Questions

Can I build a triplex in Austin without rezoning? +
Yes, on a lot zoned SF-1, SF-2 or SF-3 with at least 5,750 square feet. The use table in Section 25-2-491 of the Austin Land Development Code marks three-unit residential as a permitted use in those three districts, so City staff approve it against the written rules. In SF-5, SF-6 and the MF districts the three-unit use is absent, and townhouse, condominium or multifamily rules apply.
How much floor area can three homes have on an Austin lot? +
Inside the Subchapter F area of Austin, Section 25-2-773(E) limits a three-unit site to the greater of a 0.65 floor-to-area ratio or 4,350 square feet. A new home may not exceed the greater of 0.4 or 2,300 square feet. On a 5,750 square foot lot the site limit is 4,350 square feet, which is 1,450 square feet for each of three equal homes.
Is a triplex reviewed differently from three separate houses in Austin? +
Yes. The City of Austin's HOME page defines a triplex as a single building containing three attached units and says an applicant for one must submit a Request for Modification or Alternate Method of Compliance form with the permit application. The form is not required for other three-unit layouts, such as three detached homes or a duplex with a single home.
Do I need a site plan for three or four homes in Austin? +
A site plan is not required in Austin for construction of four or fewer residential units on a legal lot that holds four or fewer units in total, under Section 25-5-2. The work must be outside the 100-year floodplain, or the director must find an insignificant effect on the waterway. A building permit is still required.
What is a residential infill project in Austin? +
Austin Section 25-1-21 defines a residential infill project as development of a site of no more than 1.00 acre that has five to sixteen dwelling units, or that is a qualifying resubdivision of SF-1, SF-2 or SF-3 land. Section 25-5-3 treats five to 16 homes on a lot of up to 1.50 acres as a small project, and Section 25-5-112 gives the director 90 days to approve the site plan.
Where can I build townhouses in Austin? +
Townhouse residential use is permitted in Austin's SF-5, SF-6 and MF-1 to MF-6 districts under the use table in Section 25-2-491. Section 25-2-775 requires at least two connected townhouses, a lot width of 20 feet and 3,600 square feet of site area for each one. In SF-5 a townhouse group on a local residential street may have no more than six townhouses.
How many condominiums fit on an SF-6 lot in Austin? +
Austin Section 25-2-776 requires a site of at least 14,000 square feet for a condominium residential use and 3,500 square feet of site area for each condominium. A 14,000 square foot site therefore holds four. A project with fewer than 10 homes must also set aside private personal open space equal to 5 percent of the gross site area.
How tall can an apartment building be in Austin's MF districts? +
The table in Austin Section 25-2-492 sets a maximum height of 40 feet in MF-1 and MF-3, 40 feet or 3 stories in MF-2, 60 feet in MF-4 and MF-5 and 90 feet in MF-6. Near houses, the compatibility rules can lower that: within 50 feet of a triggering property a structure in MF-4 or a less restrictive district may not exceed 40 feet.
Can I build apartments on commercial land in Austin under SB 840? +
A City of Austin briefing of September 24, 2025 says SB 840 allows residential by right in the office zones NO, LO and GO and the commercial zones CR, LR, GR, L, CBD, DMU, W/LO, CS and CH. The law excludes land within 1,000 feet of a heavy industrial use and within 3,000 feet of an airport or military base. The briefing gives the density as 54 units per acre.
Do compatibility rules apply to a small apartment building in Austin? +
Austin's compatibility rules apply to a site zoned MF-4 or a less restrictive district that is within 75 feet of a triggering property, under Section 25-2-1051. A site zoned MF-1, MF-2 or MF-3 is more restrictive than MF-4. Duplex, two-unit and three-unit uses are exempt under Section 25-2-1052, and a 25-foot buffer is waived for a residential site with 16 or fewer homes.

Official sources (checked October 2026)

Austin LDC 25-2-773, duplex, two-unit and three-unit residential uses
https://library.municode.com/tx/austin/codes/land_development_code?nodeId=TIT25LADE_CH25-2ZO_SUBCHAPTER_CUSDERE_ART4ADRECEUS_SPARESPUS_S25-2-773DUTITTHITREUS
Austin LDC 25-2-3, residential uses described
https://library.municode.com/tx/austin/codes/land_development_code?nodeId=TIT25LADE_CH25-2ZO_SUBCHAPTER_AZOUSDIMADIDE_ART1ZOUS_S25-2-3REUSDE
Austin LDC 25-2-491, permitted, conditional and prohibited uses
https://library.municode.com/tx/austin/codes/land_development_code?nodeId=TIT25LADE_CH25-2ZO_SUBCHAPTER_CUSDERE_ART2PRUSDERE_DIV1RETA_S25-2-491PECOPRUS
Austin LDC 25-2-492, site development regulations
https://library.municode.com/tx/austin/codes/land_development_code?nodeId=TIT25LADE_CH25-2ZO_SUBCHAPTER_CUSDERE_ART2PRUSDERE_DIV1RETA_S25-2-492SIDERE
Austin LDC 25-2-775, townhouses
https://library.municode.com/tx/austin/codes/land_development_code?nodeId=TIT25LADE_CH25-2ZO_SUBCHAPTER_CUSDERE_ART4ADRECEUS_SPARESPUS_S25-2-775TO
Austin LDC 25-2-776, condominium residential use
https://library.municode.com/tx/austin/codes/land_development_code?nodeId=TIT25LADE_CH25-2ZO_SUBCHAPTER_CUSDERE_ART4ADRECEUS_SPARESPUS_S25-2-776COREUS
Austin LDC 25-2-780, multifamily residential use
https://library.municode.com/tx/austin/codes/land_development_code?nodeId=TIT25LADE_CH25-2ZO_SUBCHAPTER_CUSDERE_ART4ADRECEUS_SPARESPUS_S25-2-780MUREUS
Austin LDC Chapter 25-2, Subchapter C, Article 3, Division 1, residential district regulations
https://library.municode.com/tx/austin/codes/land_development_code?nodeId=TIT25LADE_CH25-2ZO_SUBCHAPTER_CUSDERE_ART3ADRECEDI_DIV1REDI
Austin LDC Chapter 25-2, Subchapter C, Article 10, compatibility standards
https://library.municode.com/tx/austin/codes/land_development_code?nodeId=TIT25LADE_CH25-2ZO_SUBCHAPTER_CUSDERE_ART10COST
Austin LDC 25-1-21, definitions
https://library.municode.com/tx/austin/codes/land_development_code?nodeId=TIT25LADE_CH25-1GEREPR_ART2DEME_S25-1-21DE
Austin LDC 25-5-2, site plan exemptions
https://library.municode.com/tx/austin/codes/land_development_code?nodeId=TIT25LADE_CH25-5SIPL_ART1SIPLGE_DIV1SIPLRENO_S25-5-2SIPLEX
Austin LDC 25-5-3, small projects
https://library.municode.com/tx/austin/codes/land_development_code?nodeId=TIT25LADE_CH25-5SIPL_ART1SIPLGE_DIV1SIPLRENO_S25-5-3SMPR
Austin LDC 25-5-112, director's approval of a site plan
https://library.municode.com/tx/austin/codes/land_development_code?nodeId=TIT25LADE_CH25-5SIPL_ART2ADSIPL_S25-5-112DIAP
Austin LDC 25-7-67, modified drainage standards for residential infill
https://library.municode.com/tx/austin/codes/land_development_code?nodeId=TIT25LADE_CH25-7DR_ART3REAP_S25-7-67MODRSTREIN
City of Austin, HOME amendments
https://www.austintexas.gov/development-services/home-amendments
City of Austin, Ordinance No. 20250306-037 (residential infill, PDF)
https://services.austintexas.gov/edims/document.cfm?id=447819
City of Austin, SB 840 briefing to the Codes and Ordinances Joint Committee, September 24, 2025 (PDF)
https://services.austintexas.gov/edims/document.cfm?id=459173
Local Government Code chapter 218, added by SB 840 and SB 2477 (2025)
https://statutes.capitol.texas.gov/Docs/LG/htm/LG.218.htm#218.002
SB 840 (2025), enrolled bill text
https://capitol.texas.gov/tlodocs/89R/billtext/html/SB00840F.htm
VanPlex newsletter

Get new guides by email

New VanPlex guides and articles on multiplex rules, building costs and permits, sent to your inbox.

General information, not legal advice. Texas has no statewide zoning code. Each city writes its own rules, and deed restrictions recorded on a lot can forbid what the city allows. Confirm current requirements with the city planning department, read the deed restrictions for your lot, and talk to a Texas-licensed attorney or architect before you buy land or file plans.

Planning a multiplex in Austin?

VanPlex builds multiplexes in British Columbia, Canada. For a lot in Austin, our team makes a custom proforma by hand and emails it to you in 24 to 48 hours.

Get a proforma for your address