David Babakaiff
Written by David Babakaiff · Co-Founder, VanPlex | 25+ Years BC Construction Last reviewed: October 2026

San Antonio | Historic and Overlay Districts

San Antonio Historic, Conservation, Aquifer and Military Overlay Districts

A San Antonio lot can have a second set of zoning rules in addition to its base district, the main zone on the lot. The Unified Development Code (UDC) calls these overlay districts. Seven of them change what a homeowner or small builder can do: historic districts, neighborhood conservation districts, the Edwards Recharge Zone, and four airport and military overlays. This page gives the rules and numbers for each. The San Antonio overview gives the short version of the base zoning.

San Antonio overlay districts in six facts

  • Where an overlay district requires lower densities, greater setbacks or otherwise greater standards than the base zoning district, the more restrictive standard applies. Source: San Antonio UDC 35-330
  • A certificate of appropriateness must be secured before Development Services issues a permit for work on a historic landmark or a property in a historic district. Source: San Antonio UDC 35-608
  • A historic district application goes to public hearing only after owners of at least 51 percent of the properties in the proposed boundary give written support. Source: San Antonio UDC 35-605
  • The UDC lists 10 adopted neighborhood conservation districts, from South Presa/South St. Mary's Sts. (NCD-1) to Monte Vista Terrace (NCD-10). Source: San Antonio UDC 35-335
  • Inside the city, a project over the Edwards Aquifer Recharge Zone may have no more than 30 percent gross impervious cover if single-family and 50 percent if multi-family. Source: San Antonio City Code 34-930
  • Residential uses are prohibited in the military airport overlay zones, except existing residences, vacant platted single-family lots, and one house per acre on unplatted land in MAOZ-2. Source: San Antonio UDC 35-334

How an Overlay Works

UDC 35-330 says overlay districts "address special siting, use and compatibility issues which require use and development regulations in addition to those found in the underlying zoning districts." The base district still applies. The overlay adds to it, and "the more restrictive standard applies" where the two differ. The zoning designation is "the regular zone symbol and the overlay district symbol as a suffix." A lot can carry more than one overlay.

Overlay Symbol Main effect on housing Section
Historic district or landmark H Certificate of appropriateness before permits for exterior work; demolition only on proof of unreasonable economic hardship 35-333, 35-605 to 35-620
Neighborhood Conservation District NCD-1 to NCD-10 Design standards for new buildings and street facades; certificate of compliance before a building permit 35-335
Edwards Recharge Zone District ERZD Impervious cover limits, a San Antonio Water System letter of certification, and limits on uses 35-332, 35-521, City Code 34-901 to 34-980
Airport Hazard Overlay District AHOD Permit needed for a structure or tree above 200 feet or above a 100 to 1 slope from the nearest runway 35-331
Military Airport Overlay Zones MAOZ-1, MAOZ-2 New residential use prohibited, with three exceptions 35-334
Military Sound Attenuation Overlay MSAO-1, MSAO-2 Homes built to reduce outside noise by at least 25 dBA 35-339.05
Military Lighting Overlay Districts MLOD Outdoor lighting limits within five miles of four installations 35-339.04

Source: San Antonio UDC, Article III, Division 4 and Article VI, Division 2, Supplement 25 Update 1, and City Code Chapter 34, Supplement 146, read through the sections in the last column.

The same division of the UDC also holds river improvement, viewshed, mission protection and corridor overlays. This page does not cover them.

Historic Districts and Landmarks

City Council creates a historic district by zoning ordinance, and such districts "shall bear the word "historic" (H) in their zoning designation" (Section 35-605). The process starts with an application to the historic preservation officer, a City official. Staff of the Office of Historic Preservation hold at least one public meeting, and the officer then mails a ballot to the owners. The application moves to a hearing only when the officer "has received verifiable written support from the owners of at least fifty-one (51) percent of the properties within the proposed historic district boundary." Each property counts once, and government-owned properties are left out of the count.

Three bodies then act in turn. The Historic and Design Review Commission (HDRC) makes its recommendation within 30 days. The Zoning Commission holds a hearing within 45 days of receiving it, and City Council holds a hearing within 45 days after that. Once an application is forwarded for public hearing, the historic rules already apply to every property inside the proposed boundary as interim controls.

The main effect is the certificate of appropriateness, a City approval that the work fits the district. Section 35-608 says it "is required and shall be secured by a party prior to the issuance of a permit from the department of development services." It covers work "to the exterior of a subject property": construction, alterations, additions, signs, landscaping, parking lots, relocation and demolition. "Non-public interior spaces are exempt." The commission reviews plans against the Historic Design Guidelines adopted by City Council.

  • Small jobs. Section 35-611 lets the historic preservation officer approve "certain minor alterations, additions, ordinary repairs or maintenance" without a commission hearing. Its list starts with repairs that use the same material and design, repainting, and reroofing in the same type and color of material.
  • Commission deadline. The commission makes its written recommendation "within sixty (60) days after the historic preservation officer's receipt of the completed application." If it does not, the application "shall be deemed recommended by the commission for approval."
  • Decision. The city manager or designee, who is the historic preservation officer unless the city manager names someone else, notifies the applicant within ten business days of receiving the recommendation.
  • Appeal. A decision to approve or deny may be appealed to the Board of Adjustment, which may not consider new evidence.
  • Time limits. After the certificate is issued, the applicant "must secure permits within one hundred eighty (180) days and start work within one hundred eighty (180) days of issuance of permits," or the certificate is void.
  • Reapplying. After a denial, a new application for the same work may not be filed for one year, unless the commission waives the limit.
Office of Historic Preservation fee FY 2027 amount
Certificate of Appropriateness, residential None
Certificate of Appropriateness, new construction (1 to 4 units) $500.00 + $200 per additional unit
Certificate of Appropriateness, new construction (5 to 24 units) $1,200.00
Certificate of Appropriateness, work without approval $500.00
Demolition application, non-commercial $50.00
Determination of non-contributing status (30-day review) $350.00
Historic Assessment, valid for 5 years (45 to 60-day review) $350.00

Source: City of San Antonio, FY 2027 Development Fee Schedule, revised September 2026, Office of Historic Preservation table, which the schedule marks as not subject to surcharges, read October 8, 2026.

If the $500.00 covers the first unit, a new fourplex in a historic district comes to $500.00 plus $200 for each of three additional units, or $1,100.00. Confirm the count with the Office of Historic Preservation.

Demolition and Historic Review

Historic status also limits demolition. Section 35-614(e) says "No certificate shall be issued for demolition of a historic landmark or property located within a historic district unless the applicant provides sufficient evidence to support a finding by the commission of unreasonable economic hardship." The owner must show that no reasonable use or return is possible, that the building cannot be adapted for another use, and that the owner "has owned the property for a minimum of two (2) years and has failed to find a purchaser or tenant for the property during the previous two (2) years." The commission may not weigh conditions that are not unique to the property, and the code gives "the current economic climate" as an example.

The commission "shall not hold a public hearing on the application for sixty (60) days" after the Office of Historic Preservation receives it, so the officer can look for an alternative. If demolition is approved, a fee is charged on the square footage of the approved replacement plan. The UDC lists $2,000.00 for 0 to 2,500 square feet, $5,000.00 for 2,501 to 10,000 square feet, and up to $30,000.00 over 50,000 square feet. The FY 2027 fee schedule prints the first band as "0-2000 sf" and starts the second at 2,501 square feet, so the two documents differ on a replacement plan of 2,001 to 2,500 square feet. Ask the Office of Historic Preservation which band it applies.

A building with no historic status is also checked. Section 35-620 says all applications for permits to demolish buildings "which are not historic landmarks or located within a historic district shall be referred to the city HPO," the historic preservation officer, who decides within 30 days after a complete application whether the building may have historic, cultural, architectural or archaeological significance. If it has none, "a demolition permit may be issued immediately." If it is found eligible for designation, interim controls apply and the owner must follow the Section 35-614 process. Section 35-606 limits interim controls on an eligible property to the lesser of 180 days from notification or action by City Council.

Historic Tax Incentives

Section 35-618 offsets some of the cost. Ad valorem tax is the yearly property tax based on assessed value. The section lists these cases:

  • Residence in need of substantial repair. After verified rehabilitation, the property "shall have no assessed value for ad valorem taxation for a period of five (5) tax years." It is then assessed "at a fifty (50) percent rate for an additional consecutive five-year period."
  • Homeowners in newer districts. In a historic district designated after October 1, 2000, owner-occupied residential properties qualify for a credit "amounting to twenty (20) percent of the assessed City of San Antonio ad valorem property tax" for ten tax years, with five more years for a resident who stays the full ten.
  • Rental properties. Owners of a "substantially rehabilitated" landmark who lease 40 percent or more of the rental units to low-income tenants can qualify for zero assessed ad valorem taxes for ten years.

The rehabilitation exemptions start with an application to the Office of Historic Preservation and end with a sworn statement of completion. The Texas property tax page covers the rest of the tax bill.

Neighborhood Conservation Districts

Section 35-335 describes neighborhoods that "are worthy of preservation and protection, but may lack sufficient historical, architectural or cultural significance at the present time to be designated as historic districts." A neighborhood conservation district (NCD) gives them their own set of design rules. To qualify, an area must contain at least one blockface, which is all the lots on one side of a block, and at least "seventy-five (75) percent of the land area in the proposed district was improved at least twenty-five (25) years ago." Owners of 51 percent of the land area, or 51 percent of the property owners, may start the request.

District Name Plan adopted
NCD-1 South Presa/South St. Mary's Sts. November 14, 2002
NCD-2 Alta Vista May 8, 2003
NCD-3 Ingram Hills September 9, 2004
NCD-4 Whispering Oaks February 24, 2005
NCD-5 Beacon Hill Area December 15, 2005; amended and restated June 22, 2017
NCD-6 Mahncke Park January 17, 2008; amended and restated April 11, 2019
NCD-7 Jefferson April 16, 2009
NCD-8 Woodlawn Lake Area November 18, 2010
NCD-9 Westfort Alliance October 20, 2011
NCD-10 Monte Vista Terrace May 6, 2021

Source: San Antonio UDC 35-335(c), Supplement 25 Update 1.

Each NCD has its own ordinance and plan. The design standards must cover, at a minimum, eight items: building height and number of stories; building size and massing; principal elevation features; lot size and coverage; front and side setbacks, the distances a building keeps from the lot lines; off-street parking and loading; roof line and pitch; and paving. They may also cover density, garage entrance location, driveways and fences. A plan adopted on or after April 1, 2019 "shall not include any standards or requirements relating to building materials or methods," and older plans may not be changed on those points.

Two rules make an NCD matter for a second or third home. First, "In the event of a conflict between the provisions of a specific neighborhood conservation district ordinance and the regular base zoning district regulations, the provisions of the neighborhood conservation district ordinance shall control." So an NCD lot size or setback replaces the Table 310-1 number. Second, no building permit is issued for new construction, or for an alteration or addition to the street facade of an existing building, "without the submission and approval of design plans and the issuance of a certificate of compliance by the development services director." Ordinary repair and maintenance with the same design is outside the standards. Read the plan for your NCD before you design.

The Edwards Recharge Zone

The Edwards Recharge Zone District (ERZD) covers the land where, in the words of Section 35-332, "the Edwards and associated limestone formations come to the surface to provide a recharge area for the underground water supply." Recharge means surface water soaking down into the aquifer. The district "is designed as an overlay to the regular zoning districts," and a use must be permitted in both the base district and the overlay.

Housing is allowed. The ERZD column of Table 311-1 marks one-family, two-family, three-family and four-family dwellings, and multi-family up to 33 units per acre, with a P. Multi-family at 40 units per acre or more is marked S, which needs City Council approval, with an engineering report on wastewater main capacity.

The limits are on impervious cover, the roofs and paving that stop water from soaking into the ground. Section 35-332(c) says no development may occur in the ERZD "except in compliance with the Edwards Aquifer Protection Standards (chapter 34, article VI, division 6 of the City Code)." That division sorts projects into three categories. Category 1 is a project with a permit application filed before the division took effect, which keeps the earlier rules. Category 2 is any other project inside the city limits. Category 3 is a project in the extraterritorial jurisdiction (ETJ), the land outside the city limits where the City applies some rules.

Type of development Category 2, inside the city Category 3, in the ETJ
Single-family residential 30 percent 15 percent
Multi-family residential 50 percent 15 percent
Commercial 65 percent 15 percent

Source: San Antonio City Code Sections 34-930 and 34-935, maximum gross impervious cover, Supplement 146. In Category 3 an engineer's documents may support a higher figure.

Section 34-908 defines impervious cover as roads and "parking areas, buildings, pools, patios, sheds, driveways, private sidewalks, and other impermeable construction covering the natural land surface." Vegetated water quality basins and public sidewalks are not counted. Measured on a single 6,000 square foot lot, 30 percent is 1,800 square feet of roof, driveway and patio in total.

  • Letter of certification. Section 34-910 says no development may start on regulated land in the recharge zone "unless and until a letter of certification is issued by the resource protection and compliance department of the San Antonio Water System." The letter expires if progress is not shown within three years.
  • Floodplain buffer. A buffer zone runs beside each floodplain preservation area. Its width is 60 feet on slopes of 0 to 2.5 percent and rises to 100 feet on slopes over 10 percent, and impervious cover is not allowed in it except for the few activities the code lists.
  • Rezoning. A rezoning is a change of zoning district. Staff recommendations on zoning cases in the ERZD include a report from the San Antonio Water System. The FY 2027 fee schedule lists an "ERZD Environmental Impact Fee" of 1.5 times one-half of the zoning fee.
  • State small-lot law. Section 35-398.03 says the SB 15 small-lot rules do not affect measures "related to aquifer recharge zones or the protection of an aquifer."

Airport and Military Overlays

Section 35-331, the Airport Hazard Overlay District, is a height rule. Within an airport hazard area, no structure or tree may be built or grown "at a height greater than two hundred (200) feet above the ground or above a 100 to 1 (100:1) slope from the nearest point of the nearest runway of any airport unless a permit therefor shall have been applied for and granted." A 100 to 1 slope rises one foot for every 100 feet of distance from the runway. A house or fourplex is far below 200 feet, so the slope is the part to check on land close to a runway.

The Military Airport Overlay Zones in Section 35-334 limit use, and they limit housing directly. The clear zones at the ends of military runways measure 3,000 feet by 3,000 feet. MAOZ-1 is the area that "extends approximately five thousand (5,000) feet in length and three thousand (3,000) feet in width beyond the clear zone," and MAOZ-2 "extends approximately seven thousand (7,000) feet in length" beyond MAOZ-1. The section lists "Residential uses" as prohibited, with three exceptions. Platted land is land divided into lots by a recorded map called a plat.

  • Existing residences "may be repaired and enlarged provided (1) the number of dwelling units is not increased" and the other rules of the district are met. An ADU or a conversion to a duplex adds a unit.
  • Vacant platted lots zoned for single-family use may hold a single-family house, and "may not be subdivided into more than one (1) additional lot."
  • Unplatted property zoned single-family may be platted for houses in MAOZ-2 at a density of no more than one single-family residence per acre.

Final plats in these zones must carry a notice that the property "is subject to noise and/or aircraft accident potential which may be objectionable." The two state-law sections in the UDC also leave this land out: the small-lot rules in Section 35-398.03 and the commercial-land housing rules in Section 35-312 both exclude land within 3,000 feet of an airport or military base.

Two more overlays change how a home is built without limiting the number of homes. Section 35-339.05, the Military Sound Attenuation Overlay, sets standards for Camp Bullis (MSAO-1) and Martindale (MSAO-2). Habitable parts of noise sensitive buildings, which include "single-family and multi-family dwellings," must achieve "an outside to inside noise level reduction (NLR) of at least twenty-five (25) a-weighted decibels (dBA)," or be built with walls and ceilings rated at a sound transmission class of 40. A decibel is a unit of loudness, and sound transmission class is a rating of how well a wall blocks sound. Section 35-339.04, the Military Lighting Overlay, limits outdoor lighting "five (5) miles or less from the perimeter of Camp Bullis/Camp Stanley, Randolph Air Force Base, Lackland Air Force Base and Martindale Army Air Field," with the strictest limits within three miles.

Best For

  • ✓ A lot with no overlay suffix after its base zone on the City zoning map.
  • ✓ A rehabilitation of a historic house, which can qualify for the tax relief in Section 35-618.
  • ✓ An NCD lot where the adopted plan allows the height, lot coverage and setbacks the design needs.

Usually Fails When

  • ✕ The plan depends on demolishing a building that counts toward a historic district.
  • ✕ A single-family project inside the city over the recharge zone needs more than 30 percent impervious cover.
  • ✕ The plan adds a dwelling unit to a home in a military airport overlay zone.

What To Verify Before Spending Money

  • → Every suffix in the zoning designation of the lot, since a lot can carry more than one overlay.
  • → The adopted plan and design standards for the specific historic district or NCD.
  • → Distance to the nearest airport or military base, and whether the lot is in MAOZ-1 or MAOZ-2.

Where to Go Next

Related on VanPlex: the San Antonio overview, property tax in Texas, and insurance and flood in Texas.

Frequently Asked Questions

How do I know if my San Antonio lot is in an overlay district? +
San Antonio UDC 35-330 says the zoning designation of a lot in an overlay is the base zone symbol with the overlay symbol as a suffix. Its example is a parcel zoned "RE" in the Edwards Recharge Zone district, shown as "RE" (ERZD). Section 35-605 says historic districts carry the word historic, or H, in their zoning designation.
Do I need approval to remodel a house in a San Antonio historic district? +
Exterior work does. San Antonio UDC 35-608 requires a certificate of appropriateness before Development Services issues a permit for work on a property in a historic district. Non-public interior spaces are exempt unless an ordinance designates them. Section 35-611 lets the historic preservation officer approve minor alterations, ordinary repairs and maintenance without a commission hearing.
How long does a certificate of appropriateness take in San Antonio? +
Under San Antonio UDC 35-608(f), the Historic and Design Review Commission makes its written recommendation within 60 days after the historic preservation officer receives a complete application. If it does not, the application is deemed recommended for approval. The city manager or designee then notifies the applicant within 10 business days of receiving the recommendation.
Can I demolish a house in a San Antonio historic district? +
Only on a strict showing. San Antonio UDC 35-614 says no demolition certificate is issued for a landmark or a property in a historic district unless the applicant proves unreasonable economic hardship. The owner must have owned the property for at least two years and failed to find a buyer or tenant in that time. The commission holds no hearing for 60 days after the application.
Are there tax breaks for restoring a historic house in San Antonio? +
Yes. San Antonio UDC 35-618(f) says a historic residence that is "substantially rehabilitated" has no assessed value for ad valorem taxation for five tax years after verification, then is assessed at 50 percent for five more. In a historic district designated after October 1, 2000, owner-occupied homes also qualify for a credit of 20 percent of the City property tax for 10 tax years.
What is a neighborhood conservation district in San Antonio? +
A San Antonio neighborhood conservation district (NCD) is an overlay under UDC 35-335 for areas that are distinctive but may lack the significance for historic designation. Each one has its own ordinance and design standards, covering at least height, building size, lot size and coverage, setbacks, parking and roof line. Where the NCD ordinance conflicts with the base district, the NCD ordinance controls.
How much of a lot can be covered over the Edwards Aquifer in San Antonio? +
For a project inside the San Antonio city limits that is not covered by an earlier permit application, City Code 34-930 limits gross impervious cover to 30 percent for single-family residential, 50 percent for multi-family residential and 65 percent for commercial development. Impervious cover includes buildings, driveways, parking areas, pools, patios and private sidewalks. In the extraterritorial jurisdiction the limit is 15 percent.
Can I build a new house near Lackland or Randolph in San Antonio? +
It depends on the overlay. In a San Antonio military airport overlay zone, UDC 35-334 prohibits residential uses with three exceptions: existing residences may be repaired and enlarged without adding units, vacant platted single-family lots may hold a house, and unplatted single-family land in MAOZ-2 may be platted at no more than one house per acre.
Do homes near Camp Bullis need soundproofing in San Antonio? +
In the San Antonio military sound attenuation overlay districts, yes. UDC 35-339.05 names Camp Bullis as MSAO-1 and Martindale as MSAO-2 and requires habitable parts of homes to achieve an outside to inside noise level reduction of at least 25 dBA, or to use walls and ceilings with a sound transmission class rating of 40. Single-family and multi-family dwellings are both covered.
Does a building permit for a tall structure near the San Antonio airport need extra approval? +
San Antonio UDC 35-331 requires a permit before any structure or tree in an airport hazard area is built or grown higher than 200 feet above the ground, or above a 100 to 1 slope from the nearest point of the nearest runway. The section names San Antonio International Airport, Stinson Municipal Airport, Kelly Air Force Base and Randolph Air Force Base.

Official sources (checked October 2026)

San Antonio UDC 35-330, overlay districts generally
https://library.municode.com/tx/san_antonio/codes/unified_development_code?nodeId=ARTIIIZO_DIV4OVDI_S35-330GE
San Antonio UDC 35-333, historic districts and landmarks
https://library.municode.com/tx/san_antonio/codes/unified_development_code?nodeId=ARTIIIZO_DIV4OVDI_S35-333HIDILA
San Antonio UDC 35-605, designation process for historic districts
https://library.municode.com/tx/san_antonio/codes/unified_development_code?nodeId=ARTVIHIPRURDE_DIV2HIPR_S35-605DEPRHIDI
San Antonio UDC 35-608, certificate of appropriateness
https://library.municode.com/tx/san_antonio/codes/unified_development_code?nodeId=ARTVIHIPRURDE_DIV2HIPR_S35-608CEAP
San Antonio UDC 35-614, demolition of a landmark or contributing property
https://library.municode.com/tx/san_antonio/codes/unified_development_code?nodeId=ARTVIHIPRURDE_DIV2HIPR_S35-614DELACOPR
San Antonio UDC 35-618, historic tax exemption qualifications
https://library.municode.com/tx/san_antonio/codes/unified_development_code?nodeId=ARTVIHIPRURDE_DIV2HIPR_S35-618TAEXQU
San Antonio UDC 35-620, demolition permit review and historic assessment
https://library.municode.com/tx/san_antonio/codes/unified_development_code?nodeId=ARTVIHIPRURDE_DIV2HIPR_S35-620DEPEREHIAS
San Antonio UDC 35-335, NCD Neighborhood Conservation District
https://library.municode.com/tx/san_antonio/codes/unified_development_code?nodeId=ARTIIIZO_DIV4OVDI_S35-335NCNECODI
San Antonio UDC 35-332, ERZD Edwards Recharge Zone District
https://library.municode.com/tx/san_antonio/codes/unified_development_code?nodeId=ARTIIIZO_DIV4OVDI_S35-332EREDREZODI
San Antonio City Code, Chapter 34, Article VI, Division 6 (aquifer recharge zone and watershed protection)
https://library.municode.com/tx/san_antonio/codes/code_of_ordinances?nodeId=PTIICO_CH34WASE_ARTVIWAQUCOPOPR_DIV6AQREZOWAPR
San Antonio UDC 35-331, AHOD Airport Hazard Overlay District
https://library.municode.com/tx/san_antonio/codes/unified_development_code?nodeId=ARTIIIZO_DIV4OVDI_S35-331AHAIHAOVDI
San Antonio UDC 35-334, MAOZ Military Airport Overlay Zones
https://library.municode.com/tx/san_antonio/codes/unified_development_code?nodeId=ARTIIIZO_DIV4OVDI_S35-334MAMIAIOVZO
San Antonio UDC 35-339.04, Military Lighting Overlay Districts
https://library.municode.com/tx/san_antonio/codes/unified_development_code?nodeId=ARTIIIZO_DIV4OVDI_S35-339.04MILIOVDI
San Antonio UDC 35-339.05, MSAO Military Sound Attenuation Overlay District
https://library.municode.com/tx/san_antonio/codes/unified_development_code?nodeId=ARTIIIZO_DIV4OVDI_S35-339.05MSMISOATOVDI
City of San Antonio, FY 2027 Development Fee Schedule (PDF)
https://docsonline.sanantonio.gov/FileUploads/dsd/CurrentFeeSchedule.pdf
VanPlex newsletter

Get new guides by email

New VanPlex guides and articles on multiplex rules, building costs and permits, sent to your inbox.

General information, not legal advice. Texas has no statewide zoning code. Each city writes its own rules, and deed restrictions recorded on a lot can forbid what the city allows. Confirm current requirements with the city planning department, read the deed restrictions for your lot, and talk to a Texas-licensed attorney or architect before you buy land or file plans.

Planning a multiplex in San Antonio?

VanPlex builds multiplexes in British Columbia, Canada. For a lot in San Antonio, our team makes a custom proforma by hand and emails it to you in 24 to 48 hours.

Get a proforma for your address