David Babakaiff
Written by David Babakaiff · Co-Founder, VanPlex | 25+ Years BC Construction Last reviewed: October 2026

San Antonio | Lot Size and Small Lots

San Antonio Lot Size, Lot Width and Small Lots: Table 310-1 and Section 35-398.03

In San Antonio the zoning district sets the smallest lot you may create. Table 310-1 of the Unified Development Code (UDC) gives the area, street frontage and width for each district, and Section 35-515 adds the rules for lot shape, flag lots and dividing a duplex. Section 35-398.03, added on September 4, 2025, carries the state small-lot law, SB 15, for large unplatted tracts. A plat is the recorded map that divides land into lots, and an unplatted tract has none. This page gives each number with its section. The San Antonio overview gives the short version.

San Antonio lot rules in six facts

  • Table 310-1 sets minimum lots of 6,000 square feet in R-6, 5,000 in R-5, 4,000 in R-4, 3,000 in R-3, 2,000 in R-2 and 1,250 in R-1. Source: San Antonio UDC Table 310-1
  • The minimum lot width is 50 feet in R-6, 45 feet in R-5, 35 feet in R-4, 20 feet in R-3, R-2 and R-1, and 15 feet in the RM districts. Source: San Antonio UDC Table 310-1
  • A townhouse lot may be as small as 1,200 square feet and 15 feet wide, and townhouses are not subject to the minimum lot size for RM districts. Source: San Antonio UDC 35-373
  • A duplex lot may be split through the common wall into two lots, each at least 4,000 square feet and 40 feet wide, by vacating and replatting. Source: San Antonio UDC 35-515
  • A subdivision of 10 or fewer lots may have 2 flag lots, and a flag lot needs at least 15 feet of frontage at the right-of-way line. Source: San Antonio UDC 35-515
  • On an unplatted tract of five acres or more zoned for single-family homes, Section 35-398.03 bars requiring lots larger than 3,000 square feet, wider than 30 feet or deeper than 75 feet. Source: San Antonio UDC 35-398.03

Lot Dimensions by District

Table 310-1 is the "Lot and Building Dimensions Table." Section 35-310.01(a) ties it to permits: "No building permit shall be issued unless the proposed development conforms to the design regulations prescribed within the applicable zoning district." Section 35-515(c) repeats the point for new lots: inside the city, the size, width, depth and shape of lots "shall comply with the applicable zoning district regulations."

District Minimum lot (sq ft) Street frontage (ft) Minimum width (ft) Maximum width (ft) Largest single building
RE 43,560 100 120 None None
R-20 20,000 65 90 None None
R-6 6,000 30 50 150 None
R-5 5,000 30 45 150 None
R-4 4,000 20 35 150 None
R-3 3,000 15 20 None 70% of lot area
R-2 2,000 15 20 None 50% of lot area
R-1 1,250 15 20 None 45% of lot area
RM-6 6,000 15 15 150 65% of lot area
RM-5 5,000 15 15 100 65% of lot area
RM-4 4,000 15 15 80 65% of lot area
MF-18 to MF-65 None 50 50 None None

Source: San Antonio UDC 35-310.01, Table 310-1, columns (B), (E), (F), (G) and (M), Supplement 25 Update 1. "None" means the table shows a dash or an empty cell.

The rules printed under the table explain each column. Frontage is "the distance where a property line is common with a street right-of-way line." The right-of-way is the strip of public land that holds the street and sidewalk. Lot width is "the width of the lot at the front setback line," the line a building must stay behind. Maximum lot widths "apply only to detached single-family residential development." The minimum lot size column "applies only to Conventional Option, single-family detached developments," so other housing types follow their own sections, covered below.

The last column is a building size limit that only the small-lot and RM districts have. In R-3 a single building may be no larger than 70 percent of the lot area, in R-2 50 percent, in R-1 45 percent, and in the RM districts 65 percent.

The R-3, R-2 and R-1 Small-Lot Districts

Section 35-310.05a says the three districts are for "specialized housing markets such as the affordable housing market, starter homes, and empty nester homes on small lots." Four housing types may be built in them: single-family attached dwellings, single-family detached dwellings, townhouses and zero-lot line houses. A zero-lot line house sits on one side lot line, which leaves a wider yard on the other side.

The section puts limits on where these districts go:

  • R-3 size. An R-3 subdivision "shall be limited to a maximum size of thirty (30) acres including lots, street right-of-way, easements and open space."
  • R-2 and R-1 size. Zoning requests for R-2 and R-1 "shall be limited to a maximum size of two thousand nine hundred ninety-nine (2,999) square feet," a limit that does not apply to zoning cases the City starts itself.
  • No enclaves. The districts "are inappropriate for "enclave subdivisions" and are not permitted" there.
  • Parks. In R-3 the park or open space requirement is "one (1) acre for each seventy (70) units," within one mile of the homes, and a fee in place of the land is not permitted. R-1 and R-2 have no park requirement.
  • Driveways. Driveway width for R-3, R-2 and R-1 homes "shall not exceed twelve (12) feet within the street's right-of-way."

Table 310-1 and this section do not match on one point. The table prints a maximum lot size of "2.999" for R-2 and "1.999" for R-1, with a decimal point, while the text of Section 35-310.05a sets a 2,999 square foot limit on R-2 and R-1 zoning requests. The table also sends readers to "subsection 35-410.05a(b)(3)" in its Note 7, a section number that does not exist in the code; the R-3 rules are in 35-310.05a(b)(3). Ask Development Services which limit applies before you plan an R-2 or R-1 request.

Small lots can also appear inside RM zoning with no new zoning case. In RM-4, RM-5 and RM-6, "a limited number of lots may be developed as "R-3", "R-2", and "R-1" lots by right," as long as those lots "do not exceed fifteen (15) percent of the gross number" of RM lots in the development.

Frontage, Shape and Access

Section 35-515(c)(4) requires every lot to "front on a public or private street or platted irrevocable ingress/egress easement." An ingress/egress easement is a recorded right to cross a strip of land to reach a lot. The plat must carry a note that no structure, fence or wall may be placed in it. The same subsection says single-family lots "shall not front on a collector street, arterial street, or parkway" except as the street standards allow. Collector and arterial streets are the busier streets that carry traffic between neighborhoods.

On an irregular shaped lot, "a minimum street frontage of fifteen (15) feet shall be required." The term covers any lot on a cul-de-sac or next to a curve with a centerline radius under 200 feet. Subsection (c)(6) bars a plat that leaves a neighbor's land with no access.

Blocks have length limits too. A block with houses fronting a Local type B street may not be longer than 700 feet, and a street with homes fronting may not run more than 3,000 feet in total.

Flag Lots and Shared Driveways

A flag lot is a lot behind another lot that reaches the street by a narrow strip, the pole of the flag. Section 35-515(h) allows them "to allow for the more efficient use of irregularly shaped parcels of land," in limited numbers. For flag lots, the standards of this subsection replace Table 310-1.

Size of subdivision Maximum flag lots
10 or fewer lots 2 lots
11 to 50 lots 20%
51 or more lots 20%

Source: San Antonio UDC 35-515(h), Table 515-2, Supplement 25 Update 1.

  • The driveway must be at least 10 feet wide.
  • "The minimum frontage at the right-of-way line for any flag lot shall be fifteen (15) feet."
  • A shared driveway may give "access to not more than four (4) lots."
  • Flag lots "shall not be permitted where they will increase the number of lots that take their access from collector or arterial streets."
  • The pole does not count toward lot area when a lot is checked for an on-site sewage system.

Section 35-515(d)(2) permits shared driveways "in any zoning district classification," and allows pervious pavers or gravel as driveway surfaces in any residential district.

Dividing a Duplex Lot and Building Across Lot Lines

Section 35-515(g) lets the owner of a duplex turn it into two houses that can be sold separately. A lot with "two (2) attached dwelling units may be subdivided or resubdivided through the common wall into separate fee simple lots for each dwelling unit." Fee simple means full ownership of the land and the building on it. The conditions are:

  • The duplex lot "shall be vacated and replatted," which means the old plat is cancelled and a new one is recorded.
  • Each new lot "shall have a minimum lot area of four thousand (4,000) square feet and shall be at least forty (40) feet wide," except in a planned unit development.
  • Each lot gets separate utility meters, and separate water and wastewater lines that "shall not traverse any other lot."
  • Walls and floors between the two homes must be at least one-hour fire-resistive construction.

So a duplex needs a parent lot of at least 8,000 square feet and 80 feet of width to be split this way. An RM-6 lot at the 6,000 square foot minimum is too small.

The reverse case is one house on two lots. Section 35-515(a)(2) notes that some inner-city areas "were developed with lots as narrow as twenty-five (25) feet in width," and it lets one owner build a single-family structure over the common line without an amending plat. The lots must be platted, or lie in "the original 36-square mile area of San Antonio" with boundaries recorded before June 14, 1927. The owner must get a certificate of determination from the Development Services Department first. The exception covers one home only: "Under no conditions shall a duplex, tri-plex, four plex or any other multi-family dwellings be permitted without rezoning and platting." A rezoning is a change of zoning district that City Council votes on.

Lot Sizes Outside Table 310-1

Three housing types and one special district carry their own lot numbers.

  • Townhouses. Section 35-373(b) sets the minimum lot area at 1,200 square feet and the minimum lot width at 15 feet, and says townhouses "shall not be subject to the minimum lot size for RM districts in Table 310-1."
  • Cottage housing. A cottage housing development needs a site of at least 11,600 square feet, with 3,300 square feet of land per unit in RM-4, 3,900 in RM-5 and 4,800 in RM-6.
  • Infill Development Zone. Where IDZ is the base district, lots "may be platted without a minimum lot area requirement, provided that detached single-family uses shall have a minimum lot size of one thousand two hundred fifty (1,250) square feet" (Section 35-343.01(c)).
  • Houses in MF districts. Note 4 of Table 310-1 applies the R-4 lot requirements to single-family lots in an MF district.

New subdivisions next to old large-lot neighborhoods face one more rule. Under Section 35-310.01(d), where a proposed subdivision abuts an existing subdivision that was "recorded and substantially developed" when the UDC took effect and is zoned R-20 or RE, the lots along the shared edge must meet the R-20 dimensions, be at least 100 feet deep and have at least 20,000 square feet. No street may be built within 100 feet of the edge of the existing subdivision.

Section 35-372 allows extra units in return for income limits. A rezoning, master development plan or plat that sets aside 10 percent of its units as affordable housing may have 20 percent more units than Table 310-1 allows. The code works an example: a 20-acre R-6 parcel that yields 101 lots may reach 121 homes. Appendix A defines affordable housing as rental homes for households at or below 60 percent of area median income, or ownership homes at or below 120 percent.

SB 15 in San Antonio: Section 35-398.03

Section 35-398.03, "Small Lot Single-Family Development," was added by Ordinance No. 2025-09-04-0580 on September 4, 2025. It writes the state's SB 15 limits into the UDC. A property qualifies only when all three of these hold: it will be platted for small lots and is "located in an area zoned for single-family homes"; it is "five (5) acres in size or more"; and it does "not have a recorded plat."

Rule Limit on what the City may require
Lot area the City may require No more than 3,000 sq ft
Lot width the City may require No more than 30 feet
Lot depth the City may require No more than 75 feet
Front setback No more than 15 feet
Rear setback No more than 10 feet
Side setbacks No more than 5 feet
Parking No more than 1 space per unit, with no covered or off-site parking required
Open space or permeable surface No more than 30 percent
Height At least 3 full stories of up to 10 feet each must be allowed
Building bulk and wall articulation No maximum bulk and no wall articulation rule

Source: San Antonio UDC 35-398.03(c), Supplement 25 Update 1. The first three rows apply to the development; the others apply to a small lot of 4,000 square feet or less.

Compare those rows with Table 310-1. An R-6 tract of five unplatted acres would otherwise need 6,000 square foot lots that are 50 feet wide. Under Section 35-398.03 the City cannot require more than 3,000 square feet and 30 feet. Note 16 of Table 310-1 and a note under the NP table in Section 35-353 both send readers to this section.

The section keeps several City powers. It does not affect rules on rentals of less than 30 days, flooding, setbacks tied to environmental features or waterways, or "rules or other measures related to aquifer recharge zones or the protection of an aquifer." The City may require all small lots "to fully mitigate stormwater runoff," which means to hold or slow the rainwater that leaves the lot. The owner may be required to share a driveway with another lot, pay the permit fees charged for a single-family lot, and pay impact fees.

The section excludes two kinds of land. The first is land within "three thousand (3,000) feet of an airport or military base." The second is land within 15,000 feet of the boundary of a military base, "including Lackland Air Force Base or Randolph Air Force Base," when the area is a military airport overlay zone, a second set of zoning rules near military runways, with a clear zone and accident potential zone designation. The code prints "fifteen thousand (15,000)" with the word "feet" left out. The historic and overlay districts page describes those military zones.

Lots That Are Already Too Small

Some older San Antonio lots are below the current minimum for their district; the code itself notes inner-city lots as narrow as 25 feet. Section 35-702(c) says "A substandard lot may be used for any uses permitted in the applicable zoning district," and it defines a substandard lot as one that fails the area or width rule "because of a change in the applicable zoning district regulations, annexation, condemnation of a portion of the lot, or other governmental action."

Section 35-516(k) covers a lot that a government project made smaller. If the lot area or width was cut by no more than 20 percent, the director "shall issue a building permit." If a vacant lot was cut by more than 20 percent, the director may approve a building site as long as the buildings cover no more than 40 percent of what remains.

Dividing land needs a plat unless an exception applies. Section 35-430(c) lists the exceptions, for example a division into parts greater than five acres inside the city where each part has access and no public improvement is dedicated. The plats, permits and fees page covers the plat types and their costs.

Best For

  • ✓ An RM-4 lot of 4,000 sq ft or more, which the 15-foot frontage and width rules fit on narrow sites.
  • ✓ A duplex on a lot of at least 8,000 sq ft and 80 feet of width, which can be split through the common wall.
  • ✓ Five or more unplatted acres zoned single-family, away from airports and military bases.

Usually Fails When

  • ✕ A split would leave an R-6, R-5 or R-4 lot under its minimum area, width or frontage.
  • ✕ A single existing platted lot is expected to qualify for the 3,000 sq ft rule in Section 35-398.03.
  • ✕ A subdivision of 10 or fewer lots needs more than 2 flag lots.

What To Verify Before Spending Money

  • → Lot width at the front setback line, measured on a survey, against Table 310-1.
  • → Whether the lot is platted, and whether the plat or deed restrictions set their own lot rules.
  • → Distance from the tract to the nearest airport or military base before relying on Section 35-398.03.

Where to Go Next

Related on VanPlex: the San Antonio overview, SB 15 and small lots in Texas, and how Texas zoning works.

Frequently Asked Questions

How wide does a lot have to be in San Antonio? +
San Antonio UDC Table 310-1 sets the minimum lot width at 50 feet in R-6, 45 feet in R-5, 35 feet in R-4, and 20 feet in R-3, R-2 and R-1. The RM-6, RM-5 and RM-4 districts need 15 feet. The table measures width at the front setback line. Street frontage is a separate, smaller number: 30 feet in R-6 and R-5.
Can I split my lot into two lots in San Antonio? +
Dividing a San Antonio lot needs a plat unless an exception in UDC 35-430(c) applies, and each new lot must meet the size, width and frontage in UDC Table 310-1 for its zoning district. An R-4 lot needs 4,000 square feet, 35 feet of width and 20 feet of street frontage. A split of four or fewer lots on an existing street, with no new street or utility extension, is a minor subdivision.
Can I sell each half of a duplex separately in San Antonio? +
Yes, if the lot is large enough. San Antonio UDC 35-515(g) lets a lot with two attached dwelling units be divided through the common wall into separate lots. The duplex lot must be vacated and replatted, and each new lot needs at least 4,000 square feet and 40 feet of width. Each lot needs its own utility meters and water and wastewater lines.
Are flag lots allowed in San Antonio? +
Yes, in limited numbers. San Antonio UDC Table 515-2 allows 2 flag lots in a subdivision of 10 or fewer lots and 20 percent of the lots in a larger one. A flag lot needs at least 15 feet of frontage at the right-of-way line and a driveway at least 10 feet wide. A shared driveway may serve no more than four lots.
What is the smallest townhouse lot allowed in San Antonio? +
San Antonio UDC 35-373(b) sets the minimum townhouse lot at 1,200 square feet, with a minimum width of 15 feet. Townhouses are not subject to the minimum lot size for RM districts in Table 310-1. Each lot needs 100 square feet of contiguous open area, and a townhouse development may not exceed 40 units per gross acre outside the TOD district.
Does the San Antonio small-lot section apply to my existing lot? +
No, unless the land is part of a large unplatted tract. San Antonio UDC 35-398.03 applies only to property that is five acres or more, has no recorded plat, is in an area zoned for single-family homes, and will be platted for small lots. A single lot in an existing platted subdivision does not meet those tests, so Table 310-1 and its district minimum still apply to it.
What counts as a small lot under San Antonio UDC 35-398.03? +
San Antonio UDC 35-398.03(a) defines a small lot as "a residential lot that is four thousand (4,000) square feet or less." On a qualifying tract, a small lot cannot be required to have a front setback over 15 feet, a rear setback over 10 feet, side setbacks over 5 feet, or more than one parking space per unit.
Can I build one house across two lots I own in San Antonio? +
San Antonio UDC 35-515(a)(2) allows a single-family structure over a common property line when one owner holds all the lots, the building is for single-family use only, and the owner gets a certificate of determination from Development Services first. The lots must be platted, or lie in the original 36-square mile area with boundaries recorded before June 14, 1927.
What is an R-3 lot in San Antonio? +
R-3 is a San Antonio small-lot single-family district with a 3,000 square foot minimum lot, 15 feet of street frontage and a 20-foot minimum width in Table 310-1. UDC 35-310.05a limits an R-3 subdivision to 30 acres and requires one acre of park or open space for each 70 units, with no fee in place of the land.
Is there a density bonus for affordable homes in San Antonio? +
Yes. San Antonio UDC 35-372, Table 372-1, gives a 20 percent density bonus when 10 percent of the units are set aside as affordable housing, and a 10 percent bonus when 5 percent are deeply affordable. It applies to a rezoning, master development plan or subdivision plat. Resale and re-rental prices are controlled for 50 years.

Official sources (checked October 2026)

San Antonio UDC 35-310.01, Table 310-1 (lot and building dimensions)
https://library.municode.com/tx/san_antonio/codes/unified_development_code?nodeId=ARTIIIZO_DIV2BAZODI_S35-310.01GE
San Antonio UDC 35-310.05a, R-3, R-2 and R-1 districts
https://library.municode.com/tx/san_antonio/codes/unified_development_code?nodeId=ARTIIIZO_DIV2BAZODI_S35-310.05ASIMIREDI
San Antonio UDC 35-398.03, Small Lot Single-Family Development
https://library.municode.com/tx/san_antonio/codes/unified_development_code?nodeId=ARTIIIZO_DIV7SUUSRE_S35-398.03SMLOSIMIDE
San Antonio UDC 35-515, lot layout regulations
https://library.municode.com/tx/san_antonio/codes/unified_development_code?nodeId=ARTVDEST_DIV4LOLAHEDEINST_S35-515LOLARE
San Antonio UDC 35-516, setback and frontage regulations
https://library.municode.com/tx/san_antonio/codes/unified_development_code?nodeId=ARTVDEST_DIV4LOLAHEDEINST_S35-516SEFRRE
San Antonio UDC 35-373, attached dwellings
https://library.municode.com/tx/san_antonio/codes/unified_development_code?nodeId=ARTIIIZO_DIV7SUUSRE_S35-373ATDW
San Antonio UDC 35-372, affordable dwelling units
https://library.municode.com/tx/san_antonio/codes/unified_development_code?nodeId=ARTIIIZO_DIV7SUUSRE_S35-372AFDWUN
San Antonio UDC 35-343.01, IDZ Infill Development Zone
https://library.municode.com/tx/san_antonio/codes/unified_development_code?nodeId=ARTIIIZO_DIV5SPDI_S35-343.01IDINDEZOCOCHZOAPSUAFNO12018
San Antonio UDC 35-430, subdivision rules and plat exceptions
https://library.municode.com/tx/san_antonio/codes/unified_development_code?nodeId=ARTIVPR_DIV4SU_S35-430APGERU
San Antonio UDC 35-702, nonconforming uses and lots of record
https://library.municode.com/tx/san_antonio/codes/unified_development_code?nodeId=ARTVIIVERINOUS_DIV1NOUS_S35-702COLAUSPRST
San Antonio UDC Appendix A, definitions
https://library.municode.com/tx/san_antonio/codes/unified_development_code?nodeId=APXADERUIN_S35-A101DERUIN
VanPlex newsletter

Get new guides by email

New VanPlex guides and articles on multiplex rules, building costs and permits, sent to your inbox.

General information, not legal advice. Texas has no statewide zoning code. Each city writes its own rules, and deed restrictions recorded on a lot can forbid what the city allows. Confirm current requirements with the city planning department, read the deed restrictions for your lot, and talk to a Texas-licensed attorney or architect before you buy land or file plans.

Planning a multiplex in San Antonio?

VanPlex builds multiplexes in British Columbia, Canada. For a lot in San Antonio, our team makes a custom proforma by hand and emails it to you in 24 to 48 hours.

Get a proforma for your address