San Antonio | Zoning Districts
San Antonio Zoning Districts: R, RM and MF Districts and Homes per Lot
San Antonio puts every lot in a zoning district, and the district decides how many homes the lot may hold. The rules are in Chapter 35 of the City Code, the Unified Development Code (UDC). Two tables hold the main rules: Table 310-1 sets lot size and density, and Table 311-1 lists the dwelling types each district allows. This page reads both, district by district. The San Antonio overview gives the short version.
San Antonio zoning districts in six facts
- UDC 35-303 divides San Antonio into 16 residential base zoning districts, from RP (Resource Protection) to MF-65 (Urban Multi-Family). Source: San Antonio UDC 35-303
- Table 311-1 permits a detached one-family house in every residential district and a two-family dwelling only in RM-6, RM-5, RM-4 and the MF districts. Source: San Antonio UDC 35-311
- A three-family dwelling is permitted in RM-5, RM-4 and the MF districts, and a four-family dwelling in RM-4 and the MF districts. Source: San Antonio UDC 35-311
- Table 310-1 sets a maximum density of 7 units per acre in R-6, 9 in R-5 and 11 in R-4, and 18 to 65 units per acre in the six MF districts. Source: San Antonio UDC Table 310-1
- Only one primary use may be located on a residential lot, and no more than one principal building may be built on a lot in a residential district unless the code allows it. Source: San Antonio UDC 35-311 and 35-515
- A protested rezoning that allows more housing units passes on a majority vote of all councilmembers, unless owners of 20 percent or more of the land to be rezoned protest. Source: San Antonio UDC 35-421
How the UDC Sorts Land
UDC 35-303 says the city "is hereby divided into" base zoning districts, overlay districts and special districts, shown on the official zoning map. A base district is the main zone on a lot. An overlay district adds a second set of rules on top of the base zone, for example in a historic district. A special district, such as the Infill Development Zone, replaces the usual base rules with its own.
The section lists 16 residential base districts under the heading "Residential Base Zoning Districts." They fall into four groups. RP, RE and R-20 are large-lot districts. R-6, R-5, R-4 and R-3 are single-family districts. RM-6, RM-5 and RM-4 are "Residential Mixed" districts. MF-18 to MF-65 are multi-family districts. In R-20 down to R-2 and in the RM districts, the number in the name is the minimum lot size in thousands of square feet; R-1 is the exception at 1,250 square feet. The number in an MF name is the maximum number of units per acre.
The code is not consistent on two districts. Section 35-303 names R-3 and stops there. Table 310-1 and Section 35-310.05a also set rules for R-2 and R-1, with minimum lots of 2,000 and 1,250 square feet. Section 35-310.01(b) says Table 310-1 governs when it conflicts with the drawings in the district sections, so treat R-2 and R-1 as districts that exist, and confirm the zone of any lot on the City's zoning map.
Homes Allowed in Each Residential District
The table below joins three parts of the code: the district names in Section 35-303, the minimum lot size and maximum density in Table 310-1, and the dwelling rows of Table 311-1, the residential use matrix. Density is the number of homes for each acre of land. An acre is 43,560 square feet.
| District | Name in the UDC | Minimum lot | Maximum units per acre | Dwelling types permitted by right |
|---|---|---|---|---|
| RP | Resource Protection | 10 acres | 0.1 | Detached house |
| RE | Residential Estate | 43,560 sq ft | 1 | Detached house |
| R-20 | Residential Single-Family | 20,000 sq ft | 2 | Detached house |
| R-6 | Residential Single-Family | 6,000 sq ft | 7 | Detached house, attached house or townhouse, zero lot line house |
| R-5 | Residential Single-Family | 5,000 sq ft | 9 | Same as R-6 |
| R-4 | Residential Single-Family | 4,000 sq ft | 11 | Same as R-6 |
| R-3, R-2, R-1 | Single-Family Residential (small lot) | 3,000, 2,000 and 1,250 sq ft | None listed | Same as R-6 |
| RM-6 | Residential Mixed | 6,000 sq ft | 7 | R-6 types, plus a two-family dwelling |
| RM-5 | Residential Mixed | 5,000 sq ft | 9 | R-6 types, plus two-family and three-family dwellings |
| RM-4 | Residential Mixed | 4,000 sq ft | 11 | R-6 types, plus two-family, three-family and four-family dwellings |
| MF-18 | Limited Density Multi-Family | None listed | 18 | All of the above, plus multi-family to 18 units per acre |
| MF-25 | Low Density Multi-Family | None listed | 25 | All of the above, plus multi-family to 25 units per acre |
| MF-33 | Multi-Family | None listed | 33 | All of the above, plus multi-family to 33 units per acre |
| MF-40 | Multi-Family | None listed | 40 | All of the above, plus multi-family to 40 units per acre |
| MF-50 and MF-65 | Multi-Family and Urban Multi-Family | None listed | 50 and 65 | All of the above, plus multi-family to 50 or 65 units per acre |
Sources: San Antonio UDC 35-303, Table 310-1 and Table 311-1, Supplement 25 Update 1. The names for R-2 and R-1 come from the title of Section 35-310.05a.
Table 311-1 uses three marks. A "P" means the use "is permitted by right within the zoning district." By right means City staff approve the use against the written rules, with no public vote. An "S" means the use is allowed "only after review and approval of a specific use permit," which Section 35-423 says City Council grants. A blank cell means the use "is not allowed within the respective zoning district."
Read across the dwelling rows and the pattern is plain. "Dwelling - 1 Family (Detached)" has a P in every column. "Dwelling - 1 Family (Attached or Townhouse)" and "Dwelling, Zero Lot Line" start at R-6. "Dwelling - 2 Family" has a P only under RM-6, RM-5, RM-4 and the MF columns. "Dwelling - 3 Family" starts at RM-5, and "Dwelling - 4 Family" starts at RM-4. The multi-family rows start at MF-18.
What the Dwelling Names Mean
Appendix A of the UDC defines each type, and the definitions decide which row a project falls in.
- Two-family dwelling (duplex). "A detached house designed for and occupied exclusively as the residence of not more than two (2) families, each living as an independent housekeeping unit."
- Three-family dwelling (triplex) and four-family dwelling (quadraplex). A detached structure "on a platted single lot" with common walls or common floors and ceilings between the units, for no more than three or four families. A platted lot is one created by a recorded map called a plat.
- Multi-family dwelling. "A dwelling or group of dwellings on one (1) lot containing separate living units for five (5) or more families." A fourplex has four units, so this term does not cover it.
- Townhouse. "A single-family dwelling unit constructed in a group of three (3) or more attached units in which each unit extends from foundation to roof." Each townhouse sits on its own lot.
- Zero lot line. A building placed so that one or more sides "rests directly on or immediately adjacent to the lot line."
An accessory dwelling, such as a backyard cottage, is an accessory use under Sections 35-370 and 35-371, and Table 311-1 has no row for it in these districts. The ADUs and duplexes page covers it.
Density and the RM Exception
The density column of Table 310-1 is "expressed in dwelling units per gross acre." Gross acre means the whole site, before streets and open space are taken out. Seven units per acre on a 6,000 square foot lot comes to 0.96 of a unit, so the density number alone would stop a second home on an RM-6 lot of the minimum size.
Section 35-310.06 removes that limit for the three RM districts. The table density "may be exceeded" when the lot meets the minimum lot size for the district and the number of dwellings "is limited to two (2) units for RM-6, three (3) units for RM-5, and four (4) units for RM-4." The same section adds a building rule: "Multi-unit construction on lots one-third (⅓) of an acre in size or smaller, shall be within a single structure." One-third of an acre is 14,520 square feet.
The MF districts have no minimum lot size in Table 310-1, only a density. Note 4 of the table covers houses built there: "Single-family lot development within an "MF" multi-family zoning district shall meet the minimum lot requirements for an "R-4" zoning district." Section 35-310.07 allows up to 10 percent more units per acre in MF-40, MF-50 and MF-65 when the required parking is in a parking garage.
Two general rules limit every residential lot. Section 35-311(a) says "Only one (1) primary use may be located on any residential lot." Section 35-515(a) says that in residential districts "no more than one (1) principal building" may be put up on a lot unless the chapter permits it. Two separate houses on one R-4 lot do not fit either rule.
The NP Neighborhood Preservation Districts
Table 311-1 has three more columns: NP-15, NP-10 and NP-8. Section 35-353 says these districts protect land zoned "R-A," "R-1a," "R-1b," or "R-1c" before June 4, 2001, and existing platted subdivisions "substantially developed with single-family detached dwelling units." The stated aim is to keep those subdivisions from being divided further. The permitted uses "are the same as the uses permitted within an "R-6" district."
| District | Minimum lot (sq ft) | Maximum units per acre | Frontage (ft) | Lot width (ft) | Front setback (ft) | Rear setback (ft) |
|---|---|---|---|---|---|---|
| NP-8 | 8,000 | 5 | 40 | 60 | 20 | 20 |
| NP-10 | 10,000 | 4 | 45 | 65 | 20 | 20 |
| NP-15 | 15,000 | 3 | 55 | 75 | 20 | 30 |
Source: San Antonio UDC 35-353(c), Supplement 25 Update 1. Each NP district has a 5-foot side setback and a height limit of 35 feet or 2½ stories.
The front setback in an NP district is 20 feet, twice the 10 feet that Table 310-1 sets for R-6. A setback is the distance a building must keep from a lot line, and frontage is the lot edge along the street. Section 35-353 also says the NP districts "are not appropriate for the down zoning of unsubdivided parcels or tracts."
Overlays, Special Districts and Commercial Land
The letters after the base zone on a zoning map are overlays. Section 35-330 gives the example of a parcel zoned "RE" inside the Edwards Recharge Zone district, whose designation is "RE" (ERZD). Where an overlay "requires lower densities, greater setbacks, or otherwise imposes greater standards," the "more restrictive standard applies." The historic and overlay districts page covers seven overlays that affect housing.
Two more ways to build more than one home are outside the base residential districts. The Infill Development Zone (IDZ) is a special district for older parts of the city, with three levels of density. Section 35-312, added by Ordinance No. 2025-09-04-0580 on September 4, 2025, also allows housing of three or more units on land zoned office, commercial or light industrial, with no rezoning. Both are on the three or more homes page.
Rezoning a Lot to RM or MF
When the base district does not allow the dwelling type, the owner can ask for a different district. UDC 35-421 sets the steps.
- Meeting first. The section says "a pre-application conference is required for all applications," held with the zoning section of the Development Services Department.
- Who may file. The owner, or a contract purchaser or agent with the owner's specific written consent.
- Completeness review. The director checks that the application is complete "within two (2) working days of application submittal."
- Plan check. Within five working days, staff decide whether the request fits the City's master plan, its adopted plan for how land is used, or the land use part of a neighborhood, community or sector plan. If it does not, the applicant must also file a plan amendment.
- Zoning Commission. The commission holds at least one public hearing and sends a report to City Council.
- City Council. Notice of the Council hearing is published before the 15th day before the hearing. The applicant must present the case to Council "within six (6) months from the date of the commission's final consideration," or a new application and fees are required.
Section 35-421(f) lists the points Council weighs and says "No single factor is controlling." One of them speaks to single lots: "Amendatory ordinances shall not rezone a single city lot when there have been no intervening changes or other saving characteristic." Proof that a small tract is unsuitable as zoned, or that the area has changed, "may justify" the rezoning. Another names housing: a strong public policy in favor of the rezoning may be considered, and the examples include "a need for affordable housing."
The protest rules are in subsection (e)(3). Under the general rule, a written protest by owners of at least 20 percent of the land covered, or of the adjoining land within 200 feet, raises the vote to three-fourths of all Council members. San Antonio wrote the 2025 state change into subsection (D). If the rezoning "would result in allowing more housing units than the current zoning allows," a protest by adjoining owners counts only when they own 60 percent of the land within 200 feet, and then "an affirmative vote by a majority of all councilmembers is required." Owners of 20 percent or more of the land to be rezoned can still force the three-fourths vote. Protests must reach Development Services by 4:00 p.m. on the business day before the Council hearing. The HB 24 page explains the state law behind subsection (D).
| Zoning fee | FY 2027 amount |
|---|---|
| Zoning base fee, 0 to 0.5 acres | $914.25 |
| Zoning base fee, 0.51 to 5 acres | $2,035.50 |
| Zoning base fee, 5.01 to 10 acres | $3,659.30 |
| Expedited zoning case, 0 to 0.5 acres | $1,828.50 |
| Zoning case postponement request | $465.75 |
| Zoning verification letter | $402.50 per letter |
| Board of Adjustment case, homestead exemption | $460.00 |
| Board of Adjustment case, non-homestead | $690.00 |
Source: City of San Antonio, FY 2027 Development Fee Schedule, revised September 2026, "Zoning" and "Board of Adjustment" tables, read October 8, 2026. The schedule says fees are subject to a 4% Technological Improvement surcharge and a 4% Development Services surcharge unless noted.
UDC Appendix C prints lower zoning fees, for example $795.00 for 0 to 0.50 acres. The City's published FY 2027 schedule is newer, so budget with the schedule and confirm the amount when you file.
Variances and Lots That No Longer Fit
A variance is permission from the Board of Adjustment to depart from a dimension rule, such as a setback. UDC 35-482 lists six findings the board must make. One of them rules out using a variance to add units: the variance "will not authorize the operation of a use other than those uses specifically authorized for the district." Another requires that the owner's difficulty comes from "unique circumstances existing on the property" that the owner did not create and that "are not merely financial." A variance lapses if no building starts within twelve months of the hearing, and the board may grant up to two twelve-month extensions.
Some older lots are smaller than the current district minimum. Section 35-702(c) protects them: "A substandard lot may be used for any uses permitted in the applicable zoning district." A use that the zoning no longer allows, such as an old duplex on R-5 land, is a nonconforming use. It may continue, but if it "is discontinued for twelve (12) months, any future use of such premises shall be in conformity with the provisions of this chapter."
Best For
- ✓ A lot already zoned RM-6, RM-5 or RM-4 that meets the district minimum lot size.
- ✓ An MF-zoned lot, where two, three and four-family dwellings are all permitted by right.
- ✓ A rezoning request that fits the land use plan for the area and adds housing.
Usually Fails When
- ✕ The plan needs a duplex or more on R-6, R-5 or R-4 land with no rezoning.
- ✕ The plan puts two separate principal buildings on one single-family lot.
- ✕ A variance is used to try to add a dwelling type the district does not list.
What To Verify Before Spending Money
- → The base district and every overlay suffix on the City zoning map for the lot.
- → The land use plan for the area, which a rezoning must be consistent with.
- → The current zoning fee in the FY 2027 Development Fee Schedule.
Where to Go Next
Related on VanPlex: the San Antonio overview, how Texas zoning works, and HB 24 and zoning protests.
Frequently Asked Questions
How many residential zoning districts does San Antonio have?
Can I build a duplex on an R-6 lot in San Antonio?
What is the difference between R-6 and RM-6 zoning in San Antonio?
What does MF-33 mean in San Antonio zoning?
Does San Antonio count a fourplex as multi-family?
How do I rezone a lot in San Antonio?
How much does a rezoning application cost in San Antonio?
Can neighbors block a rezoning in San Antonio?
What is an NP district in San Antonio?
Can a variance let me build a duplex in a single-family district in San Antonio?
Can I build on a San Antonio lot that is smaller than its zoning district requires?
Official sources (checked October 2026)
Get new guides by email
New VanPlex guides and articles on multiplex rules, building costs and permits, sent to your inbox.
Planning a multiplex in San Antonio?
VanPlex builds multiplexes in British Columbia, Canada. For a lot in San Antonio, our team makes a custom proforma by hand and emails it to you in 24 to 48 hours.
Get a proforma for your address