Oakland | Zoning Districts
Oakland Zoning Districts: RH, RD, RM and RU Zones and How Many Homes Each Allows
A zoning district, or zone, is the label the City puts on each lot to say what may be built there. Oakland's zones are in Title 17 of its Municipal Code, the Oakland Planning Code. This page explains the residential zones, how many homes each allows on a lot, and the overlay zones that add rules on top. The code was read in Supplement 59, whose history table lists ordinances through No. 13868, adopted December 16, 2025. The Oakland and Berkeley overview compares Oakland with its neighbor.
Oakland zoning in six facts
- The Oakland Planning Code has four families of residential zones: RH Hillside Residential (RH-1 to RH-4), RD Detached Unit Residential, RM Mixed Housing Type Residential (RM-1 to RM-4) and RU Urban Residential (RU-1 to RU-5). Source: Oakland Planning Code, Chapters 17.13 to 17.19
- In the RD zone and all four RM zones, a lot may hold 1 to 2 units on any legal lot, 3 units on a lot of at least 3,000 sq ft, and 4 units on a lot of at least 4,000 sq ft. Source: Tables 17.15.03 and 17.17.03
- For 5 or more units, the RM zones allow one unit per 1,750 sq ft of lot area in RM-1, 1,500 in RM-2, 1,250 in RM-3 and 1,000 in RM-4. Source: Oakland Planning Code, Table 17.17.03
- RU-1 allows one regular unit per 1,000 sq ft of lot area, RU-2 one per 750 sq ft and RU-3 one per 450 sq ft; in RU-4 and RU-5 the density depends on the height area shown on the zoning map. Source: Oakland Planning Code, Tables 17.19.03 and 17.19.04
- RH-1, RH-2 and RH-3 allow one primary home per lot; RH-4 allows two units on lots of 8,000 sq ft or more, only outside the S-9 fire zone and on streets paved at least 26 feet wide. Source: Oakland Planning Code, Table 17.13.03
- These unit counts come from Ordinance No. 13763, adopted October 3, 2023, which also created the Two- to Four-Family Dwelling facility type. Source: City Council report, August 22, 2023
Four Families of Residential Zones
Oakland's residential zones run from the hills to the main streets. The RH Hillside Residential zones are for "residential areas that are primarily characterized by detached structures on hillside lots." The RD Detached Unit Residential zone covers areas "primarily characterized by a mix of single-unit structures, small multi-unit buildings, and neighborhood businesses where appropriate." The RM Mixed Housing Type Residential zones are "typically located near the City's major arterials," which are the large through streets. The RU Urban Residential zones are for "multi-unit, mid-rise or high-rise residential structures in locations with good access to transportation and other services."
Each family has numbered zones. The number goes up as the zone allows more. RH-1 is for "single-family living on lots of one acre or more," RH-2 for lots of at least 25,000 square feet, RH-3 for lots of at least 12,000 square feet, and RH-4 for lots of 6,500 to 8,000 square feet, "typically appropriate in already developed areas of the Oakland Hills." In the RM family, RM-1 is a mix of "single family homes and duplexes," and RM-2 adds "townhouses, small multi-unit buildings." RM-3 has "somewhat higher densities than in RM-2," in the code's own words, and RM-4 is "on or near the City's major arterials." RU-1 is for "low-rise" buildings, RU-2 and RU-3 for "low-rise or mid-rise" buildings, and RU-4 and RU-5 for "mid-rise, and high rise residential structures on the City's major corridors." RU-5 adds "ground floor neighborhood businesses."
Density, in zoning, means how many homes the land may hold. Oakland writes it in two ways. For small projects it gives a count tied to lot size, such as "4 units on minimum 4,000 sf. lots." For larger projects it gives a lot area per unit, such as one unit per 1,500 square feet. In that second form a smaller number means more homes on the same lot.
Homes per Lot in Each Zone
| Zone | Name | Homes allowed (up to 4) | 5 or more homes |
|---|---|---|---|
| RH-1, RH-2, RH-3 | Hillside Residential | 1 primary dwelling unit per lot | Not allowed |
| RH-4 | Hillside Residential 4 | 1 primary dwelling unit per lot; 2 units on lots of 8,000 sq ft or more | Not allowed |
| RD | Detached Unit Residential | 1 to 2 units on any legal lot; 3 on 3,000 sq ft; 4 on 4,000 sq ft | Multifamily Dwelling prohibited |
| RM-1 | Mixed Housing Type 1 | Same 1 to 4 unit rule as RD | 1 unit per 1,750 sq ft of lot area |
| RM-2 | Mixed Housing Type 2 | Same 1 to 4 unit rule as RD | 1 unit per 1,500 sq ft of lot area |
| RM-3 | Mixed Housing Type 3 | Same 1 to 4 unit rule as RD | 1 unit per 1,250 sq ft of lot area |
| RM-4 | Mixed Housing Type 4 | Same 1 to 4 unit rule as RD | 1 unit per 1,000 sq ft of lot area |
| RU-1 | Urban Residential 1 | 1 unit per 1,000 sq ft of lot area | Same rate |
| RU-2 | Urban Residential 2 | 1 unit per 750 sq ft of lot area | Same rate |
| RU-3 | Urban Residential 3 | 1 unit per 450 sq ft of lot area | Same rate |
| RU-4, RU-5 | Urban Residential 4 and 5 | Set by height area (Table 17.19.04) | 1 unit per 500 to 200 sq ft |
Source: Oakland Planning Code Table 17.13.03, Table 17.15.03, Table 17.17.03 and Tables 17.19.03 and 17.19.04, Supplement 59. Accessory dwelling units are counted separately.
The RD and RM rule is the same for the first four homes: "1-2 units on any legal lot; 3 units on minimum 3,000 sf. lots; 4 units on minimum 4,000 sf. lots." A legal lot is a lot that was lawfully created. So a 2,500 square foot RD lot holds two units, a 3,500 square foot lot holds three, and a 5,000 square foot lot holds four. In the RD zone four is the limit, because the RD facility table lists a "Multifamily Dwelling" as prohibited.
The RM zones keep going past four. Table 17.17.03 adds "For 5 or more units" a lot area per unit: 1,750 square feet in RM-1, 1,500 in RM-2, 1,250 in RM-3 and 1,000 in RM-4. A worked example by VanPlex: a 6,000 square foot RM-4 lot divided by 1,000 gives 6 units. The same lot in RM-2 gives 4 units under the 5-plus rule, so the owner would use the plain four-unit rule instead. A 7,500 square foot RM-2 lot gives 5 units.
The RU zones use the lot area method for every project. RU-1 allows "1 unit per 1,000 sf. of lot area," RU-2 one per 750 square feet and RU-3 one per 450 square feet. By VanPlex arithmetic, a 5,000 square foot RU-1 lot holds 5 regular units and a 4,500 square foot RU-3 lot holds 10. RU-1 and RU-2 lots must be at least 2,500 square feet; RU-3, RU-4 and RU-5 lots at least 4,000 square feet. The RU zones also allow more small units: rooming units and efficiency units, which are homes with one room plus a kitchen and no more than 400 square feet, need half the lot area of a regular unit in RU-1 to RU-3.
RU-4 and RU-5: Density by Height Area
In RU-4 and RU-5 the zoning map adds a height area number to each lot, and Table 17.19.04 ties both height and density to it. The table below shows the regular dwelling unit column.
| Height area | Maximum height | Maximum stories | Lot area per regular unit |
|---|---|---|---|
| 35 | 35 ft | 3 | 500 sq ft |
| 45 | 45 ft | 4 | 400 sq ft |
| 65 | 65 ft | 6 | 300 sq ft |
| 95 | 95 ft | 8 | 200 sq ft |
| 125 | 125 ft | 12 | 200 sq ft |
Source: Oakland Planning Code Table 17.19.04, Height, Floor Area Ratio, Density, and Open Space Regulations for the RU-4 and RU-5 Zones Only.
These zones also set a minimum height on wide streets. In the 65, 95 and 125 height areas, a new main building on a lot next to a street at least 100 feet wide must reach a "permitted height minimum" of 35, 45 or 55 feet. One-family houses are prohibited in RU-4 and RU-5, though an accessory dwelling unit is allowed "when there is an existing One-Family Dwelling on a lot."
Building Types and Where They Are Allowed
Oakland sorts homes by building type, which the code calls a facility. Chapter 17.10 gives three types. A "One-Family Dwelling" contains "one Regular Dwelling Unit on a parcel," a "Two- to Four-Family Dwelling" contains "two (2) to four (4) Regular Dwelling Units or Efficiency Dwelling Units on a parcel," and a "Multifamily Dwelling" contains "five (5) or more." Each type may also have accessory dwelling units. The facility tables in each zone chapter mark each type P for permitted or with a dash for prohibited.
| Zone | One-Family Dwelling | Two- to Four-Family Dwelling | Multifamily Dwelling (5+) |
|---|---|---|---|
| RH-1 to RH-3 | P | Prohibited | Prohibited |
| RH-4 | P | P | Prohibited |
| RD | P | P | Prohibited |
| RM-1 to RM-4 | P | P | P |
| RU-1 to RU-3 | P | P | P |
| RU-4 and RU-5 | Prohibited (ADU allowed with an existing house) | P | P |
Source: Oakland Planning Code Tables 17.13.02, 17.15.02, 17.17.02 and 17.19.02 (permitted facilities), and Sections 17.10.640 to 17.10.680. P means permitted.
The RH-4 row needs a careful reading. Table 17.13.02 marks a Two- to Four-Family Dwelling as permitted in RH-4, but the density row in Table 17.13.03 allows at most "2 dwelling units on lots 8,000 sf. or greater." The density row is the limit, so RH-4 holds a duplex at most. The City's August 22, 2023 report on the rezoning says the same: "three or more units are not allowed in the zone." Additional Regulation 18 adds two conditions for the second unit: the lot must be outside the S-9 Fire Safety Protection Combining Zone, and "the minimum pavement width along the entire length of the adjoining street is at least twenty-six (26) feet," including every street to the nearest arterial.
Where the Missing Middle Rules Came From
The City's report defines "Missing Middle" housing as "a range of building types with multiple units" that are "compatible in scale and form with detached single-family homes." The City Council report of August 22, 2023 on Phase 1 of the 2045 General Plan Update says the Planning Code changes "redefine certain zoning designations and change development standards to allow for a range of multi-unit" or missing middle "housing types and affordable housing in existing neighborhoods, including currently single-family-dominated neighborhoods." The ordinance it describes made "Updates to the Detached Unit Residential (RD) Zone," changed density in the RM, RH-4 and RU zones, and created "a New Two- to Four-Family Residential Facility Type."
That ordinance is No. 13763, adopted October 3, 2023, and every residential zone chapter now carries it in its history note. The same report explains a choice on lot coverage, the share of a lot that buildings may cover. Staff "removed the maximum lot coverage standards for three or more units" in RD, RM-2 and RM-3, so lot coverage and floor area limits now apply to lots with one or two units alone. They kept those limits in RH-4 "as three or more units are not allowed in the zone." The three or more homes page covers what the 2023 rules allow for triplexes and fourplexes, and the parking, setbacks and height page has the building limits.
Combining Zones That Add Rules
A combining zone is a second layer of zoning placed over the base zone. Its rules add to the base zone rules, and some replace them for projects that opt in. On the map it appears next to the base zone, for example RD/S-9. The combining zones that matter most for small housing projects are these:
- C Residential Commercial Combining Zone. Used with the RM zones "to allow for expanded commercial uses." Where it applies, "the C Residential Commercial Combining Zone permitted uses supersede those of the primary zone."
- S-7 Preservation Combining Zone. For "structures, other physical facilities, sites, and areas of special importance due to historical association" (Chapter 17.84). Design review must find the project "will not substantially impair the visual, architectural, or historic value" of the site.
- S-20 Historic Preservation District Combining Zone. For "larger areas, often with a large number of residential properties that may not be individually eligible for landmark designation but which as a whole constitute a historic district" (Chapter 17.100B).
- S-9 Fire Safety Protection Combining Zone. For lots in or next to Very High Fire Hazard Severity Zones on narrow streets or long dead ends (Chapter 17.88). It limits accessory dwelling units, as the hills, fire zone and creeks page explains.
- S-13 Affordable Housing Combining Zone. An optional program. Qualifying affordable projects get "Unlimited residential density that fits within the allowed building envelope" and two extra stories (Chapter 17.95).
- S-14 Housing Sites Combining Zone. Applies to the sites listed in the 2023-2031 Housing Element and "seeks to ensure that sites within the S-14 Zone are developed with residential uses" (Chapter 17.96).
- S-8 SB 79 Combining Zone. Added by Ordinance No. 13875, adopted March 16, 2026, after Supplement 59. It maps every parcel within half a mile of a BART station or AC Transit Tempo stop and says whether the state transit law applies (ordinance text).
Two more combining zones change parking. The zone chapters say "additional parking standards apply within the S-11 and S-12 Zones," which are the Site Development and Design Review Combining Zone (Chapter 17.92) and the Residential Parking Combining Zone (Chapter 17.94). Read the full zone label on the map before you count homes.
Design Review in Every Residential Zone
Each residential chapter has the same section: "no Building Facility, Designated Historic Property, Potentially Designated Historic Property, Telecommunications Facility, Sign, or other associated structure shall be constructed, established, or altered in exterior appearance, unless plans for the proposal have been approved pursuant to the design review procedure in Chapter 17.136." Design review is the City's check of how a building looks and fits its site. A project skips it in two ways. Section 17.136.025 exempts small work, such as repairs that match the existing design and accessory dwelling units that meet all the ADU rules. Section 17.136.023 sends projects eligible under the S-13 or S-14 zones, and fully affordable projects outside historic areas, to "By Right Residential Approval" instead, a staff check against written standards.
In the RD zone, Additional Regulation 5 adds two criteria for Regular Design Review: buildings must be "in harmony with facilities on nearby lots," and the site plan must give "a convenient, attractive, and functional living environment." The permits and fees page explains the design review tracks, including the ministerial track the City added in 2025 for projects of up to 30 units.
Where the Published Code Disagrees With Itself
Three small conflicts appear in the Supplement 59 text. First, Limitation L1 under the RD facility table still refers to "the conditionally permitted density in the RD-2 Zone," but Chapter 17.15 sets standards for a single RD zone with no RD-2 column. The development standards table is the rule that applies.
Second, the history notes under Sections 17.15.050 and 17.17.050 list "Ord. No. 13868, § 2(Exh. A), 12-16-2026," a date that has not yet arrived. The Supplement History Table lists Ordinance 13868 with the date "12-16-2025," so December 16, 2025 is the adoption date. Third, the RM height row for steep lots reads "See Table 17.17.06 for Height regulations for all lots with a footprint slope of <20%," while the table itself is titled for slopes ">20%." The table title matches the row label, so Table 17.17.06 applies to steep lots.
The published code is also behind the City Council's actions. Ordinance No. 13875 (the S-8 zone), Ordinance No. 13874 (S-14 changes) and Ordinance No. 13894 (ADU and other changes, July 21, 2026) were adopted after the ordinances that Supplement 59 lists. For any section one of these ordinances changed, read the adopted ordinance next to the code.
Best For
- ✓ RD or RM lots of 4,000 sq ft or more, which allow four homes under the 2023 rules.
- ✓ RM-4 and RU lots, where lot area per unit allows five or more homes.
- ✓ RU-4 and RU-5 lots in the 65-foot height area or higher, at 300 sq ft of lot area per unit or less.
Usually Fails When
- ✕ The lot is in RH-1, RH-2 or RH-3, which allow one primary home.
- ✕ An RH-4 lot is in the S-9 zone or on a street paved under 26 feet wide.
- ✕ The plan needs five homes on an RD lot, where Multifamily Dwellings are prohibited.
What To Verify Before Spending Money
- → The full zone label on the City zoning map, including any S or C combining zone.
- → The exact lot area, since a lot just under 3,000 or 4,000 sq ft loses a unit.
- → Whether an ordinance adopted after December 16, 2025 changed the section you rely on.
Where to Go Next
Related on VanPlex: the Oakland and Berkeley overview, the duplex to fourplex guide and the lot eligibility checks.
Frequently Asked Questions
Can I build five homes on an Oakland RD lot?
What is the difference between the RM-1 and RM-4 zones in Oakland?
How many units fit on a 6,000 square foot RM-4 lot in Oakland?
Can I build a duplex in the Oakland hills?
What does the RU-5 zone allow in Oakland?
When did Oakland allow fourplexes in former single-family areas?
Do I need design review to build a house or fourplex in Oakland?
What is a combining zone in the Oakland Planning Code?
Can a lot in Oakland's S-9 fire zone use the S-13 affordable housing rules?
Does Oakland still have an RD-2 zone?
Official sources (checked October 2026)
Get new guides by email
New VanPlex guides and articles on multiplex rules, building costs and permits, sent to your inbox.
Planning a multiplex in Oakland?
VanPlex builds multiplexes in British Columbia, Canada. For a lot in Oakland, our team makes a custom proforma by hand and emails it to you in 24 to 48 hours.
Get a proforma for your address